Figure 51. Removing the service access cover
Removing an internal RDX power cable in the 9009-41A, 9009-42A, or 9223-42H
To remove an internal RDX power cable, complete the steps in this procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. For a rack-mounted system, lift the air baffle (A) straight up as shown in Figure 52 on page 62.
For a stand-alone system, remove the air baffle (A) straight out as shown in Figure 53 on page 63.
Place the air baffle upside down on a clean area so that the foam does not collect contaminants.
RDX docking stations, removable disk drives, and power cable, for the 9009-41A, 9009-42A, or 9223-42H 61