Hearth & Home PVLP-SLP-AU Installation Instructions Manual

Power vent low profile

Advertisement

Quick Links

• Important operating
a n d m a i n t e n a n c e
instructions included.
1
Introduction

Table of Contents

1 Introduction
A. Components and Service Parts List . . . . . . . . . . . . . . . . . . 2
B. Installation of PVLP-SLP-AU. . . . . . . . . . . . . . . . . . . . . . . . 2
A. Installation of Vent Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
B. Vent/Pipe Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
C. Acceptable Vent Configurations . . . . . . . . . . . . . . . . . . . . . 8
A. Framing and Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
B. Termination Cap Clearances . . . . . . . . . . . . . . . . . . . . . . . 11
C. Installing Vent Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
A. Wiring the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
C. Time Delay Relay Settings . . . . . . . . . . . . . . . . . . . . . . . . 18
A. Installation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
B. Power Vent Operating Instructions . . . . . . . . . . . . . . . . . . 19
C. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
D. Replace Fan/Pressure Switch. . . . . . . . . . . . . . . . . . . . . . 20
E. PVLP-SLP-AU Troubleshooting . . . . . . . . . . . . . . . . . . . . 22
1
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19
PVLP-SLP-AU
Power Vent Low Profile
- Installation Instructions -
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Suitable for models under coverage
of certificates GMK10222, GMK10477,
GMK10486, GMK10489 and GMK10616
AS/NZS 5263.1.3
• Leave this manual with party
responsible for use and op-
eration.
Installation of the PVLP-SLP-AU may be done by a quali-
fied service technician only. Installation MUST comply
with local, regional, state and national codes and regula-
tions.
IMPORTANT:
Failure to read and follow these instruc-
tions may create a possible hazard and will void the ap-
pliance warranty.
These instructions must remain with the equipment.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
INTRODUCTION
The Power Vent Low Profile (PVLP-SLP-AU) is certified
for use as a horizontal termination cap only on appliances
manufactured by Hearth & Home Technologies with IPI (in-
termittent pilot ignition) gas controls. Appliances equipped
with millivolt type gas controls CANNOT use this product.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVLP-SLP-AU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hearth & Home PVLP-SLP-AU

  • Page 1: Table Of Contents

    A. Components and Service Parts List ....2 tions. B. Installation of PVLP-SLP-AU......2 IMPORTANT:...
  • Page 2: Components And Service Parts List

    The effects of the in- creased sound level can be minimized with careful plan- ning during installation of the system. Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 3: Vent Information And Diagrams

    • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated. Figure 2.1 Silicone Sealant Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 4 B. Vent/Pipe Regulations (continued) WARNING! Risk of Fire! • A minimum length run of initial vent pipe is required between the appliance and the inlet of the PVLP-SLP-AU on some appliance models. • Some models require DVP Series pipe for the initial minimum vent section directly off the appliance.
  • Page 5 FROM APPLIANCE NOTICE: If a pipe configuration includes a vertical component that goes downward, a vertical component going back upward is not allowed. Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 6 See Chart in Section 2.C: "Venting Length - Model Categories and and the PVLP-SLP-AU with certain appli- Length Requirements by Termination Type." ance models. See Table 2.1. Figure 2.2 Horizontal PVLP Orientation Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 7 See Chart in Section 2.C: "Venting Length - Model Categories and and the PVLP-SLP-AU with certain appli- Length Requirements by Termination Type." ance models. See Table 2.1. Figure 2.3 Horizontal PVLP Orientation Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 8: Acceptable Vent Configurations

    2.5 in. (64 mm) open 16-39 ft. (4.87 m - 11.88 m) 1.5 in. (38 mm) open Greater than 40 (12.19 m) Closed Table 2.3. Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 9: Framing And Clearances

    Stay inside 10 IN. of the newly installed framing as shown in Figure 3.2. (254 mm) Figure 3.2 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 10 Figure 3.4 will need to be constructed. 1-1/2 in. [38mm] 1 in. [25mm] 20-3/4 in. [527mm] 2 in. [51mm] 12 in. [305mm] Figure 3.4 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 11: Termination Cap Clearances

    4. Clearance from a fl ue terminal to a LP cylinder shall be a minimum of 1 meter. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 3.5 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 12: Installing Vent Cap

    • Cap contains silicone sealant which could affect adherence of paint. Please advise local painter of silicone content. Figure 3.9 Figure 3.6 Figure 3.10 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 13 Closed Figure 3.13 Table 3.1 8. To open the baffle, turn the adjustment bolt counter clockwise. See Figure 3.14. Figure 3.14 Figure 3.11 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 14 Remove the four screws that attach the front cover, then remove the cover. See Figure 3.16. Figure 3.15 Figure 3.16 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 15 PVLP-BEK around the entire metal flange, (SECURE FIRST) as shown in Figure 3.22 with the dotted line. Figure 3.19 PLVP-BEK Attached to Wall Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 16 Silicone (with a minimum of 300 ºF (149 ºC) continuous exposure rating) should also be applied where PVLP-SLP-AU and PVLP-BEK meet, Figure 3.24 as shown in Figure 3.21. Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 17: Electrical Information

    2. Power Vent Wire Harness 3. Timer Control Juction Box 4. Plug for 6V Power Supply (inside appliance) 5. Power Input Figure 4.2 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 18: Wall Switch And Timer Control Junction Box Installation

    6. Plug in power input cord from timer control junction box into fireplace power cord where the 6V transformer was (number 5 in Figure 4.2). Figure 4.5 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 19: Operating Instruction

    CONTROL MODULE 8K1 WIRE HARNESS CONNECT RED AND BROWN WIRES TOGETHER BROWN GROUND Figure 5.1 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 20: Maintenance

    7. Remove the two screws holding the pressure switch bracket to the exhaust housing. See Figure 5.8. 8. Remove the pressure switch. See Figure 5.10. Figure 5.5 Figure 5.2 Figure 5.6 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 21 Figure 5.7 Figure 5.8 Figure 5.9 Figure 5.10 Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...
  • Page 22: Pvlp-Slp-Au Troubleshooting

    For the location of your nearest Hearth & Home Technologies dealer, please visit www.hearthnhome.com. Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.hearthnhome.com Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19...