Relay / input / output transformer-balanced module
Hide thumbs Also See for RIO1S:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Features
Transformer-isolated, balanced line-level input
600-ohm or 10k-ohm jumper-selectable input impedance
Transformer-isolated, balanced line-level output
8-ohm, 750mW output
Input and output level controls
Relay responds to selectable priority level
External control of priority muting
N.O. or N.C. relay contacts
Input can be muted from higher priority modules, with signal fade back
Output can activate with relay priority level
Screw terminal strips
RJ11 connection with line output and dedicated N.O. relay contact
RIO1S
Relay / Input / Output
Transformer-Balanced Module
© 2007 Bogen Communications, Inc.
54-2097-01F 0706
Specifications subject to change without notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RIO1S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bogen RIO1S

  • Page 1 Input can be muted from higher priority modules, with signal fade back • Output can activate with relay priority level • Screw terminal strips • RJ11 connection with line output and dedicated N.O. relay contact © 2007 Bogen Communications, Inc. 54-2097-01F 0706 Specifications subject to change without notice.
  • Page 2: Module Installation

    All manuals and user guides at all-guides.com Module Installation 1. Turn off all power to the unit. 2. Make all necessary jumper selections. 3. Position module in front of any desired module bay opening, making sure that the module is right-side up. 4.
  • Page 3: Controls And Connectors

    All manuals and user guides at all-guides.com Controls and Connectors Level (Output) Gain (Input) Provides control over the level of Provides control over the level of output signal. input signal. RJ11 Connection This connector contains the out- Signal Output put signal and a set of normally open relay contacts.
  • Page 4: Jumper Selections

    All manuals and user guides at all-guides.com Jumper Selections Impedance Selector This module can be set for two different input impedances. When connecting to a 600-ohm source, it is desirable to have a 600-ohm matching input impedance. For typical source equipment, use 10k- ohm setting.
  • Page 5 This module’s screw terminal relay contacts can be set for normally open (N.O.) or normally closed (N.C.) operation. Output Bus Assignment The output signal can be taken from the module’s A bus, B bus, or the unit’s MIX bus. On some Bogen amplifier products, the A and B buses may be tied together.
  • Page 6: Input Wiring

    Connect the shield wire of the external signal to the ground terminal of the external equipment and to the ground terminal of the RIO1S. If the "+" signal lead can be identified, connect it to the plus "+" terminal of the RIO1S. If the external equipment polarity cannot be identified, connect either of the hot leads to the plus "+"...
  • Page 7: Output Wiring

    Connect the shield wire to the ground terminal of the external equipment and to the ground ter- minal of the RIO1S. If the "+" signal lead from the external equipment can be identified, connect it to the plus "+" terminal of the RIO1S. If the external equipment polarity cannot be identified, con- nect either of the hot leads to the plus "+"...
  • Page 8: Block Diagram

    All manuals and user guides at all-guides.com Block Diagram Relay Out (–) Gate Out (+) Relay Disabled Enabled 50 Spring Street, Ramsey, NJ 07446, U.S.A. 201-934-8500; Fax: 201-934-9832 www.bogen.com...