12. Reinstall stator by locating the dimple on the stator, and tightening the screw next to the dimple first. Next
tighten the screw 180 degrees across from the dimple. Install and tighten remaining screws. Reinstall pulley,
cam, washer, retaining ring, and dust cap.
13. Turn new base upside down and apply grease at bottom of the spring hole pockets to eliminate noise
between spring and base interaction.
14. Clean the dome area of new base with alcohol then apply corn starch.
15. Reinstall motor and pump to new base.
16. Transfer transmission and outer tub onto new base. Use spring tool 22002922 to avoid over stretching the
springs.
17. Transfer cabinet shell onto new base and reassemble washer. Be sure to reattach pressure switch hose to
back of tub, drain pump hoses with clamps to drain pump, and wire harness to motor. Check all hoses and
wires to make sure they are secure.
18. Test washer.
Page 4 of 4
9/30/2005