Suction Hose Installation - Husqvarna W 100D Operator's Manual

Hide thumbs Also See for W 100D:
Table of Contents

Advertisement

Available languages

Available languages

SUCTION HOSE INSTALLATION

Use a commercially available hose and hose connector with the hose
clamp provided with the pump (if necessary). Most hoses come with the
connectors already installed. The suction hose must be reinforced with a
noncollapsible wall or braided wire construction and cannot contain any
perforations.
Do not use a hose smaller than the pump's suction port size. Minimum
hose size: W 100D=4 inch (100 mm)
The suction hose should be no longer than necessary. Pump
performance is best when the pump is near the water level and the
hoses are short.
Use a hose clamp to securely fasten the hose connector to the suction
hose in order to prevent air leakage and loss of suction. Verify that the
hose connector sealing washer is in good condition.
Install the strainer (provided with the pump) one with equivalent hole
sizes on the other end of the suction hose, and secure it with a hose
clamp. The strainer will help to prevent the pump from becoming
clogged or damaged by debris.
Never operate the pump without the strainer installed.
Securely tighten the hose connector on the pump suction port.
SUCTION HOSE
(commercially available)
SUCTION PORT
HOSE CLAMP
CONNECTOR
HOSE CLAMP
OPERATION
SUCTION HOSE
(commercially available)
HOSE CLAMP
STRAINER
15