  • Page 1 INSTALLATION TION AND OPERATION INSTRUCTION CTIONS FOR SYM-34 34-B SYM-42 42-B SYM-50 50-B SYM-60 60-B SYM-74 74-B SYM-88 88-B SYM-100 100-B INSTALLER: LEA : LEAVE THIS MANUAL WITH THE APP E APPLIANCE. CONSUMER: RETAIN TAIN THIS MANUAL FOR FUTURE REFE REFERENCE.
  • Page 2: Table Of Contents

    Please read and carefully follow all of the instruction found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product. IMPORTANT INSTRUCTIONS ............................
  • Page 3: Important Instructions

    IMPORTANT INSTRUCTIONS 1. Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front, sides and rear of the heater. 3. Always unplug heater when not in use. 4.
  • Page 4 appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Page 5 Cautions Always install the heater in accordance with this guide. If in doubt obtain expert advice. Always make sure the electrical socket is accessible and located adjacent to, but not above the heater. Always disconnect the heater from the electrical supply before moving it, or Do’s carrying out cleaning, maintenance.
  • Page 6: Unpacking And Testing Appliance

    UNPACKING AND TESTING TING APPLIANCE Carefully remove the appliance fro ce from the box. Prior to installing the appliance, te ce, test to make sure the appliance operates p ates properly by plugging the power supply cord into a 120 V 120 Volt grounded outlet.
  • Page 7: Sym-34-B

    SYM-34-B Description This appliance has been tested in accordance Built-in Appliance Voltage 120V AC 60Hz with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United Watts 1200W Max States and Canada. If you need assistance...
  • Page 8: Sym-42-B

    SYM-42-B Description This appliance has been tested in accordance Built-in Appliance Voltage 120V AC 60Hz with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United Watts 1200W Max States and Canada. If you need assistance NO HEATER during installation, please contact your local MOTOR HEATER...
  • Page 9: Sym-50-B

    SYM-50-B Description This appliance has been tested in accordance Built-in Appliance Voltage 120V AC 60Hz with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United Watts 1200W Max States and Canada. If you need assistance NO HEATER during installation, please contact your local MOTOR HEATER...
  • Page 10: Sym-60-B

    SYM-60-B Description This appliance has been tested in accordance Built-in Appliance Voltage 120V AC 60Hz with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United Watts 1200W Max States and Canada. If you need assistance NO HEATER during installation, please contact your local MOTOR HEATER...
  • Page 11: Sym-74-B

    SYM-74-B Description This appliance has been tested in accordance Built-in Appliance Voltage 120V AC 60Hz with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United Watts 1200W Max States and Canada. If you need assistance NO HEATER during installation, please contact your local MOTOR HEATER...
  • Page 12: Sym-88-B

    SYM-88-B Description Built-in Appliance Voltage 120V AC 60Hz This appliance has been tested in accordance with the UL Standard 2021 for fixed and location Watts 1200W Max dedicated electric room appliances in the United NO HEATER States and Canada. If you need assistance MOTOR HEATER during installation, please contact your local Appliance Width...
  • Page 13: Sym-100-B

    SYM-100-B Description This appliance has been tested in accordance Built-in Appliance with the UL Standard 2021 for fixed and Voltage 120V AC 60Hz location dedicated electric room appliances in Watts 1200W Max the United States and Canada. If you need NO HEATER assistance during installation, please contact MOTOR HEATER...
  • Page 14: Bathroom Use

    FOR BATHROOM USE If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit. If receptacle is used it must be readily accessible. To prevent electric shock, please be aware that this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit.
  • Page 15: Outdoor Installations

    OUTDOOR INSTALLATIONS The SYM-B series electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance.
  • Page 16: Installation-Wall Mount

    INSTALLATION-WALL MO L MOUNT NOTE: Due to the many different fferent materials used to build walls, it is highly highly recommended that you consult your local builder bef er before you install this appliance on a wall. wall. 1. Select a location that is not pr not prone to moisture and is located at lea at least 0.91 m...
  • Page 17: Installation- Built-In

    120 Volt grounded outlet. The rough wall opening size of t ze of the fireplace: W(“) D(“) H(“) SYM-34-B 32 7/8 SYM-42-B 42 3/4 SYM-50-B 50 3/4 SYM-60-B 60 3/4...
  • Page 18 2. When the trim is removed, tak ed, take off the front glass panel. 3. Unscrew the 2 screws located ocated on each side and take off the inner side r side steel panels.
  • Page 19 4. Put the trim back onto the app he appliance and fasten with screws.(NOTE: T TE: This step is to make sure that the fireplace fits the ts the wall opening well and there is no gap be ap between the trim and the wall after installation) 5.
  • Page 20 6. Remove the trim following ST ng STEP 1. Screw back the inner side steel pa eel panels. 7. Put back the front glass pane panel and screw back the trim after you finish finish the media decoration.
  • Page 21: Installation- Semi-Flush Built-In

    See dealer for more more details. The rough wall opening size of t ze of the fireplace: W(“) D(“) H(“) SYM-34-B 32 7/8 SYM-42-B 42 3/4 SYM-50-B 50 3/4 SYM-60-B 60 3/4 SYM-74-B...
  • Page 22 2. When the trim is removed, tak ed, take off the front glass panel. 3. Unscrew the 2 screws located ocated on each side and take off the inner side r side steel panels.
  • Page 23 4. Put the trim back onto the appliance and fasten with screws.(NOTE: This step is to make sure that the fireplace fits the wall opening well and there is no gap between the trim and the wall after installation) 5. Put the fireplace into the wall opening and fix it to the wall by screwing 2 screws each side.
  • Page 24 6. Remove the trim following STEP 1. Screw back the inner side steel panels. 7. Put back the front glass panel and screw back the trim after you finish the media decoration.
  • Page 25: Hard- Wire Installation

    HARD- WIRE INSTALLATIO LATION Turn off the appliance completely pletely and let cool before servicing. Only a qu y a qualified service person should service and repair repair this electric appliance. If it is necessary to hard-wire th wire this appliance, a qualified electrician mu n must remove the cord connection, and wire the ap he appliance directly to the house hold wiring.
  • Page 26: Decorative Media Installation

    MEDIA OPTIONS The only media that comes with s with this appliance is ‘Clear decorative med media’. Consumers may purchase optional decorative me ve media if they choose. See dealer for more d ore details. Clear DECORATIVE MEDIA INSTALL TALLATION Unscrew 4 screws and take off th e off the trim.
  • Page 27: Operation

    OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. Press the Heat button repeatedly to set the heater to desired heat setting. The heater indicator LED will glow which shows the current heater settings.
  • Page 28: Remote Control Operation

    REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and the main power switch located on the bottom left hand side is at position I. Important: When operating the remote make sure you point the remote to the center of the fireplace each time you press the button.
  • Page 29: Installing Wall Thermostat

    INSTALLING WALL THERM HERMOSTAT WALL THERMOSTAT WIRING ING DIAGRAMS NOTE: The wall thermostat will t will be functioning when the heater is on the on the TEMP. setting. Wire the wall thermostat prior prior to installing the fireplace. WALL THERMOSTAT WIRING( ING(24 VAC) Install Wall Thermostat per ins er instructions provided with kit and per the...
  • Page 30: Replacement Parts

    REPLACEMENT PARTS PART NUMBER DESCRIPTION SYM-34-B SYM-42-B SYM-50-B SYM-60-B 10701358 10701359 10701346 10701347 FRONT GLASS 3200503 3201503 3202503 3203503 TRIM 10702224 10702225 10702210 10702211 EMBER BED GLASS 10702217 10702218 10702219 10702220 BACK GLASS 601141B 601141B 601141 601141 LED STRIP FOR...
  • Page 31 PART NUMBER DESCRIPTION SYM-74-B SYM-88-B SYM-100-B 10701348 10701363 10701364 FRONT GLASS 3204503 3205503 3206503 TRIM 10702212 10702226 10702227 EMBER BED GLASS 10702221 10702222 10702223 BACK GLASS 601141 601141 601141 LED STRIP FOR FLAME 601142 601142 601142 601136B 601136B 601136B LED STRIP FOR EMBER BED 601137B 601137B...
  • Page 32: Exploded View

    EXPLODED VIEW...
  • Page 33: Truble Shooting

    TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Dim or no flame Flame LED’s are burnt out Inspect the LED’s and replace them if necessary Back black cloth is falling off Change a new flicker and back and roll the flicker black cloth Ember bed is not Ember LED’s are burnt out Inspect the ember bed LED’s and...
  • Page 34: Service History

    SERVICE HISTORY This heater must be serviced annually depending on usage. Date Dealer Service Technician Service Performed Special Concerns Name Name NOTES:...
  • Page 35: Warranty

    Amantii warrants such products to be free from defects in material and workmanship for a period of two (2) years from the date of the first purchase of such products. The limited two (2) year warranty period for products also applies to any implied warranties that may exist under applicable law. Some...