7.4 Clearing Fibre Channel Controller Statistics

The system allows you to clear fibre channel controller statistics in order
to resolve system warnings. This feature clears the link down count, CRC
error count, receive error count, and any associated system warnings.
Via Web Interface
To change clear the fibre channel controller statistics via the Web
Interface:
Click on the "Fibre Channel Controller" graphic.
Click on the "Controller Setup" tab.
Click the "Clear Stats" button.

7.5 Advanced Fibre Channel Controller Options

The RamSan Text Management Interface contains several advanced
options that help to diagnose potential issues and configure the fibre
channel controllers for non-standard environments. These features are
typically used in coordination with a Texas Memory Systems technical
support contact.
7.5.1 View Fibre Channel Console
The fibre channel console provides detailed logging for the fibre channel
controllers. This feature allows Texas Memory Systems technical support
personnel to view and diagnose potential issues.