Page 6
Thermozone AD Corinte W - ADCS 1700/2200 1670/2170 Left connection Wall Right connection Ø31.5 (2x) Ø20 (3x) Fig 6a Min 180 mm Min 180 mm Fig 6b...
Page 7
Thermozone AD Corinte W - ADCS Fig 6c Fig 6d Fig 7...
Page 8
Thermozone AD Corinte W - ADCS ADCEH Ø8 2 alternatives for securing at the top.* Ø12 (2x) Ø8 for securing at the air curtain.* SE / NO / FR / RU / DE / NL / ES / PL / FI / IT / DK ) 2 alt.
Page 9
Thermozone AD Corinte W - ADCS ADCS - SIRe Fig 8 SIRe...
Page 10
Thermozone AD Corinte W - ADCS Accessories Regulations alternatives This aircurtain is supplied with an intelligent SIRe is supplied pre-programmed with quick- and well designed low voltage control release connections and is very easy to use system SIRe which can be customized for and install.
Page 12
Thermozone AD Corinte W - ADCS Competent ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP. ON/OFF (potential free contact)
Page 13
Thermozone AD Corinte W - ADCS Competent - parallell ALARM OUT (BMS) (potential free contact,max 3A, 230V) DOOR CONTACT (potential free contact) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP. ON/OFF (potential free contact)
Page 14
Thermozone AD Corinte W - ADCS Advanced BMS INDICATION OUT (potential free contact max 3A, 230V) ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL HEAT 0-10V DC IN EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP.
Page 15
Thermozone AD Corinte W - ADCS Advanced - parallell BMS INDICATION OUT (potential free contact max 3A, 230V) ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL HEAT 0-10V DC IN EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP.
Page 16
Thermozone AD Corinte W - ADCS AD Corinte W - ADCS Low temperature coil In- / outlet water temperature 70/40 °C Inlet air temp. +15 °C Incoming air temp. +20 °C Type Airflow Output Air temp. Water Output Air temp. Water position flow...
Page 17
Thermozone AD Corinte W - ADCS AD Corinte W - ADCS High temperature coil In- / outlet water temperature 130/65 °C Inlet air temp. +15 °C Incoming air temp. +20 °C Type Airflow Output Air temp. Water Output Air temp. Water position flow...
Page 18
Thermozone AD Corinte W - ADCS Technical specifications | Thermozone AD Corinte WL with water heat, coil for low tempered water < 80/60 °C 2 ∆t* Type Output* Airflow Water Sound Output Voltage Amperage Length Weight volume level* motor motor motor [kW] [°C]...
Page 19
Fixate the air curtain through the manufacturer and in accordance with the square-shaped hole. Make sure that the flat Frico mounting and operating instructions. bar is not bent when fixing. Application 7. Secure the top with an angle bracket or...
Page 20
Thermozone AD Corinte W - ADCS 3. Put the unit in place and fix the brackets to bottom. The connection from below can be the pendulums. done the following way: Note! The unit needs to be secured if hung • Flexible hoses may be drawn through from wires.
Page 21
Thermozone AD Corinte W - ADCS Maintenance To ensure performance and reliability of the air curtain inspection should be carried out regularly, at least twice a year, but this can vary depending on local conditions. This is to secure the performance of the air curtain. A clogged filter doesn’t present a risk, but will reduce the efficiency of the air curtain.
Page 22
Thermozone AD Corinte W - ADCS Monterings- og driftsvejledning Generelt 6. Der medfølger et stykke fladjern til Læs denne vejledning grundigt før installation fastgørelse af lufttæppet. Gør lufttæppet og brug. Gem denne manual til senere brug. fast gennem det firkantede hul. Kontrollér, Garantien gælder kun, hvis Thermozone-ag- at fladjernet ikke bøjes, når lufttæppet gregaterne bruges på...
Page 23
Thermozone AD Corinte W - ADCS Elektrisk installation NB! Ved tilslutning nedefra skal man undgå Aggregatet leveres med kabel og stik. at anbringe slanger eller rør, så de blokerer Installationen bør foretages med en flerpolet luftstrømmen til ventilatorerne. De kan afbryder med en kontakt adskillelse på...
Page 24
Thermozone AD Corinte W - ADCS Overophedning Sikkerhed En overophednings beskyttelse sikrer at • Det skal sikres, at området omkring undlæsningstemperaturen ikke overstiger indsugnings- og udblæsningsgitre holdes +40 °C. Skulle temperature alligevel overstige frit for materiale, der kunne forhindre dette niveau er der en overophedningsalarm. luftstrømmen igennem aggregatet! For yderligere information, se manualen for •...
Page 25
Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 Fax: +46 31 26 28 25 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...