12. ERROR CODES

You can determine the operating status by the lighting up and blinking of the LED lamp.
LED display part
/
SW107 SW108 SW109 SW112 SW110

12.2. Error code check table

PUMP DOWN
POWER/
ERROR
MODE
(L1)
(2)
(1)
(2)
(1)
(2)
(2)
(2)
(5)
(2)
(6)
(2)
(6)
(2)
(6)
(2)
(7)
(2)
(7)
(2)
(7)
(2)
(7)
(2)
(7)
(2)
(7)
(2)
(8)
(2)
(8)
(2)
(8)
(2)
(8)
(2)
(9)
(2)
(9)
(2)
(9)
(2)
(9)
(2)
(9)
(2)
(10)
(2)
(10)
(2)
(10)
Display mode
: Lights on
: Lights off
: Blink (0.5s Lights on / 0.5s Lights off)
( ) : Number of fl ashing
Button part
LED display
LOW NOISE
PEAK CUT
(L2)
(L3)
(L4)
(L5)
(1)
(1)
(2)
(15)
(2)
(3)
(5)
(1)
(2)
(3)
(3)
(4)
(7)
(4)
(6)
(6)
(6)
(4)
(5)
(7)
(8)
(9)
(1)
(3)
(5)

12.1. Error display mode

Display when an error occurs.
POWER/
ERROR
MODE
Blink
(Hi speed)
Sign "
": Lights off, "
(1) Check that the "ERROR" LED blinks, then press the [ENTER] button once.
DESCRIPTION
(L6)
Serial communication error
Indoor unit capacity error
Indoor unit error
Outdoor unit main PCB error
Inverter PCB error
IPM error
Discharge temp. sensor error
Compressor temp. sensor error
Outdoor unit Heat Ex. sensor error
Outdoor temp. sensor error
Heat sink temp. sensor error
Current sensor error
Pressure sensor error
Trip detection
Compressor motor control error
Outdoor unit fan motor 1 error
Outdoor unit fan motor 2 error
4-way valve error
Discharge temp. 1 error
Compressor temp. error
Pressure error 2
PUMP
LOW
DOWN
NOISE
(L1)
(L2)
(L3)
(L4)
": Lights on
REMARK
Serial forward transmission error immediately after
operation
Serial forward transmission error during operation
Indoor unit capacity error
Indoor unit error
Outdoor unit PCB model information error
Inverter error
Trip terminal L error
Discharge temp. sensor 1 error
Compressor temp. sensor 1 error
Heat Ex. middle temp. sensor error
Outdoor unit Heat Ex. liquid temp. sensor error
Outdoor temp. sensor error
Heat sink temp. sensor error
Current sensor 1 error (stoppage permanently)
High pressure switch 1 error
Outdoor unit discharge pressure sensor error
Outdoor unit suction pressure sensor error
Trip detection
Rotor position detection error (stoppage permanently)
Duty error
Duty error
4-way valve error
Discharge temp. 1 error
Compressor 1 temp. error
Low pressure error
PEAK
CUT
(L5)
(L6)