Connections (continued)
System example 4 (connection with commercially available controller, RS-232C daisy-chain connection)
RS-232C
RS-232C
communication
communication
connector
connector
Commercially
available
controller
You can connect up to seven cameras to the commercially available controller.
*
1
• Configure the service switches at the bottom of the unit.
For details on the service switches, see "Service switch settings" (→ page 7).
SW1 to SW3: S et the camera address to AUTO or 1 to 7.
(Set address numbers so that they do not duplicate each other.)
SW4:
Enable standard serial communication (ON).
SW7:
Set the baud rate to 9600 bps (OFF) or 38400 bps (ON) based on your commercially available contoller.
SW8:
Set the communication connector to RS-232C (ON).
• Configure the following items in the camera menu.
1. Display [System] menu - [Protocol] - [Model Select].
2. Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type.