JP3
10 -
Open and Door input common wire
11 -
N.O. Contact OPEN (controls manual door opening)
12 -
Contact DOOR (door status input)NC – Door closed NO – Door open
(detects the status of the door needed to identify the alarm condition; if not used, leave the jumper connected)
JP2 (COMPASS-READER connection)
13 -
+ Power supply
14 -
Date 1
15 -
Date Ø
16 -
- Power supply
17 -
Led A
18 -
Led B
Receives from COMPASS-READER the data of the card inserted.
It is possible to connect a maximum of 2 COMPASS-READERs to each COMPASS-485 (Fig. 3).
5) GENERATION OF MASTER CARDS
The system is controlled by three Master Cards (Master Card +, Master Card -, Master Card Jolly) which activate or deactivate the cards and
configure the functioning of access as indicated in the paragraph "Configuration of the Parameters and Management of the Cards"
To generate the Master Cards, proceed as follows:
1
Open the COMPASS-485 box
2
Set the Dip Switch 6 to ON (Fig.3)
3
Show a Standard Card (the Led will flash changing from red to green continuously)
4
Set the Dip 6 to OFF
5
The Card has now become a Master Card +, attach the supplied special adhesive label (green colour, symbol +) which will help to identify
the type of Master Card.
6
Set the Dip Switch 7 to ON (Fig.3)
7
Show a Standard Card (the Led will flash changing from red to green continuously)
8
Set the Dip 7 to OFF
9
The Card has now become a Master Card -, attach the supplied special adhesive label (red colour, symbol -), which will help to identify
the type of Master Card.
10 Set the Dip Switch 8 to ON (Fig.3)
11 Show a Standard Card (the Led will flash changing from red to green continuously)
12 Set the Dip 8 to OFF
13 The Card has now become a Master Card Jolly, attach the supplied special adhesive label (yellow colour, symbol Jolly), which will help
to identify the type of Master Card.
14 Close the COMPASS-485 box.
The Master Cards therefore allow the configuration of the system.
After using the Master Cards, place them in a safe place known only by assigned personnel along with the instructions for use.
6) CONFIGURATION OF THE PARAMETERS AND MANAGEMENT OF THE CARDS
The configuration of the parameters and card activation are obtained by showing the sequence of the Master Cards and Cards to be activated
or deactivated observing the following procedure:
Card activation:
Show the Master Card + to the reader (the Led will flash changing from red to green continuously) followed by the card for which access
activation is required (the Led turns to yellow)
Card deactivation:
Show the Master Card – to the reader (the Led will flash changing from red to green continuously) followed by the card for which access
deactivation is required (the Led turns to yellow)
If it becomes necessary to deactivate a card that has been mislaid there are two ways of doing so:
If the system is controlled by Securbase and the card code is known (all cards are supplied with a printed 6-digit code), deactivation
can be obtained by using the card software and entering the code to be deactivated in the appropriate menu.
If the system is not controlled by Securbase or the card code is not known, it is necessary to deactivate all of the cards and then
reactivate all valid cards.
Free Access (door always open):
Show the Master Card Jolly to the reader (the Led will flash changing from red to green continuously) followed by the Master Card + (the
Led turns to green)
Access Forbidden (door always closed):
Show the Master Card Jolly to the reader followed by the Master Card - (the Led turns to red)
Access with normal operation mode (opening with memorised cards only):
Show the Master Card Jolly to the reader for two consecutive times (the Led turns to yellow).
Setting of Door Relay Operation Time:
Show the Master Card + to the reader (the Led will flash changing from red to green continuously) followed by the Master Card Jolly (the
green Led flashes), from now on every time the Master Card Jolly is shown the value of the door relay operation time, expressed in seconds,
will increase. The sequence of values is the following:0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25.After 25 which
is equal to 25s, the value goes back to 0.
If the value set is 0, the relay for door opening remains active until the door is closed.
Setting of Door Control Time:
Show the Master Card – to the reader (the Led will flash changing from red to green continuously) followed by the Master Card Jolly (the
red Led flashes), from now on every time the Master Card Jolly is shown the value of the door control time, expressed in seconds, will increase.
The sequence of values is the following: 0,10,20,30,40,50,60,70,80,90,100,110,120,130,140,150,160,170,180,190,200,210,
220,230,240,250. After 250 which is equal to 250s, the value goes back to 0. If the value set is 0, the door control is disabled.
Door check:Checks the status of the door using the "DOOR" contact input, ensuring that after the door opening relay is closed, the door
is actually opened and then closed again.If opening does not occur after the "door check time", the alarm relay is commuted.If the door
is opened, it must be closed again within the "door check time", otherwise the alarm relay is commuted.