Page 2
If you use the monitor in a manner other than that for which it was intended, unpredictable behavior could ensue with possibly P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page ii CAUTION manner described in this manual.
5.4.7 TLIST ...29 5.4.8 VGET ...30 5.4.9 VLIST...31 5.4.10 VSET...32 6.0 MAINTENANCE ...33 6.1 R EPLACING THE GAS FILTER ELEMENT P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page iii ...11 ...12 ...14 ) ...20 PTIONAL ...21 )...33...
Page 4
7.3 I ...35 NVALID EADING 7.4 L ...35 7.5 C ...35 IRTY 7.6 S TATUS UTPUT UMMARY ABLE APPENDIX A – SERIAL PORT CONFIGURATION...37 P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page iv M460H ...33 ...36...
Figure 2-2 Pneumatic Connections ...12 Figure 2-3 Electrical Connections...14 Figure 2-4 Digital Output Connections ...15 Figure 2-5 Typical RS232 and RS485 Connections...17 Figure A-1 RS232/RS485 Jumpers (Controller PCA#03492) ...37 P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page v...
Page 6
Table 4-1 Auto-Zero Function...20 Table 5-1 Serial Port Configuration ...21 Table 5-2 Serial Port Command Summary...22 Table 7-1 Digital Status Outputs...34 Table 7-2 Status Output Truth Table ...36 P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page vi...
The flexibility of the software as well as the analog and digital I/O allow the Model 460H to interface with a broad range of devices for process control and data logging.
All maintenance and the first level of field troubleshooting are to be performed by the customer. NON- TELEDYNE API MANUFACTURED EQUIPMENT Equipment provided but not manufactured by Teledyne API is warranted and will be repaired to the extent and according to the current terms and conditions of the respective equipment manufacturers warranty.
The detection of ozone molecules is based on absorption of 254 nm UV light due to an internal electronic resonance of the O 3 molecule. The Model 460H uses a mercury lamp constructed so that a large majority of the light emitted is at the 254nm wavelength. Light from the lamp shines through an absorption cell through which the sample gas being measured is passed.
2.0 Installation Upon receiving the Model 460H please verify that there is no apparent shipping damage. (If damage has occurred please advise shipper first, then Teledyne API.) 2.1 Mechanical Installation 1. Mount the enclosure securely to a vertical surface. Figure 2-1 below shows the locations of the four mounting holes.
L/min. OZONE INLET WARNING - DO NOT EXCEED 30 PSIG GAS DELIVERY PRESSURE P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 12 CAUTION ozone! ZERO GAS INLET WARNING - DO NOT EXCEED 30 PSIG GAS DELIVERY...
A proper earth ground connection must be made to the receptacle labeled “Earth Ground” on the 3 pin AC connector. Failure to do so may result in a shock hazard and malfunction of the P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 13 CAUTION! IMPORTANT!
0-5 volt output. The analog output can also be optionally configured for a 4-20mA Current output. Check the serial number tag on the instrument to determine Analog Output configuration. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 14 EARTH GROUND AC LINE...
STATUS COM M454 Digital Output #1-4 (Collector) Digital Output Common (Emmiter) Opto-Isolator Figure 2-4 Digital Output Connections P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 15 Name Operation Sensor O.K. Normally On Invalid Reading Normally Off...
The pressure display input is used to display the pressure on the front panel. This input performs exactly the same function as the ‘Pressure’ buttons on the front panel. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 16...
Figure 2-5 Typical RS232 and RS485 Connections See Chapter 5 for information on the Serial Communications protocol used by the M460H. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 17 Table 2-3 Serial Port Pins Description Serial Transmit (RS485 –...
5. Observe the monitor for several more minutes at zero to ensure that it is stable. 6. The monitor is now ready to measure ozone. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 18 The display will then begin showing ozone...
460H Monitor. During normal operation, after the monitor has warmed up, the green ‘Sensor OK’ LED should be on and all other Status LED’s should be off. information on troubleshooting using the Status LED’s, see Chapter 7. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 19...
If an Auto-Zero error is detected, a manual Zero Calibration should be performed (See Section 4.1.3 Zero Calibration.) P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 20 Table 4-1 Auto-Zero Function Display Reads Holds and Flashes Concentration Value Dashes: ‘----‘...
Ascii checksum of all characters up to the # character. The checksum is optional, commands sent without the checksum(and checksum separator,) are also valid. is a carriage return, Ascii 13. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 21 Table 5-1 Serial Port Configuration Parameter Value...
Returns a compact list of current measurement parameters TLIST Returns all current measurement parameters VGET Get Single VAR value VLIST Lists all internal VARS VSET Sets value of internal VAR P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 22...
Data Parameters Sent None Response <address>:<success_flag>#<checksum><CR> Example Command: 1CAUTO<CR> Response: - Calibration Successful 1:OK#261<CR> - Calibration Failed 1:FAIL#391<CR> P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 23 Valid only if Auto-Zero option is installed in...
Instrument should be sufficiently purged with zero gas before issuing this command. Data Parameters Sent None Response <address>:<success_flag>#<checksum><CR> Example Command: 1CZERO<CR> Response: - Calibration Successful 1:OK#261<CR> - Calibration Failed 1:FAIL#391<CR> P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 24...
After the function is complete the rest of the response will be sent. No additional commands should be issued to the monitor until the function completes. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 25...
Page 26
Note that the concentration value returned shows more digits after the decimal than the front panel display. Concentration values should only be considered valid to 4 significant digits. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 26...
Note that monitor response is from previous address, but any further commands must be at new address. In the example above, after sending back the OK response, the monitor will no longer respond to commands with address 1. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 27...
Note that the concentration value returned shows more digits after the decimal than the front panel display. Concentration values should only be considered valid to 4 significant digits. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 28...
Concentration values should only be considered valid to 4 significant digits. Also, note that no checksum is sent in the response to the TLIST command. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 29...
1VGET:0<CR> - Request analog_range value Response: 1:15.0#303 - analog_range returned as 15.0 (wt%) P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 30 Description Full-Scale concentration 5.0 – 400.0 (Units are range for Analog Output current unit of measure,...
#4 comm_mode = 0.0 #5 iir_filt = 0.4 #6 conc_units = 0.0 Notes Note that no checksum is sent in the response to the VLIST command. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 31...
VAR. Response <address>:<var_value>#<checksum><CR> Example Command: 1VSET:0,15.0<CR> - Set analog_range VAR to 15.0 (wt%) Response: - VSET Successful 1:OK#261<CR> - VSET Failed 1:FAIL#391<CR> P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 32...
6.0 Maintenance 6.1 Replacing the gas filter element The Model 460H is equipped with a gas filter on the ozone inlet. These filters accept 25mm diameter glass fiber elements. Only filter elements of borosilicate glass or quartz fibers should be used. When the instrument is first installed, the sample filters should be checked at least once a week for particulate loading and replaced if necessary.
A/D converter. Adjustment by qualified service personnel is required. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 34 Table 7-1: Digital Status Outputs...
When this output is on, it indicates a loss of optical transmission through the windows in the absorption cell or a calibration fault. P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 35...
OFF, and ‘X’ indicates the output is in either state. Table 7-2: Status Output Truth Table Sensor Invalid Reading P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 36 Lamp Cell Actions Dirty Normal operation, no action...
To configure the com port for RS232 or RS485, move the 4 shunts on JP3 of the Controller PCA (#03492) to the proper position as shown in Figure A-1. RS232 RS485 Figure A-1 RS232/RS485 Jumpers (Controller PCA#03492) P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 37...
Appendix B – Pneumatic Diagram O3 Gas In Flow-Meter Filter Flow Control Orifice Azero Valve O3 Destruct Zero Gas In Measurement Cell Exhaust Out P/N 03662D Teledyne API Model 460H O 3 Monitor Operator Manual - Page 38...
Need help?
Do you have a question about the 460H NEMA and is the answer not in the manual?
Questions and answers