3
FUNCTION LIST
This chapter describes the functions of the control module. For details on the functions, refer to the following.
 MELSEC iQ-R Laser Displacement Sensor Control Module User's Manual (Application)
Sensing function
Function
Measurement function
Judgment output
Head/laser control
Zero set
Timing
Reset
Emitted light intensity search
Memory operation function
Function
Output setting copy
Memory change
Memory copy
Initialization
Save
Buffering function
Function
Self-stop
Buffering mode
Buffering type
Buffering rate
Accumulation amount
Trigger condition
Trigger delay
Trigger point
Sample trigger accumulation amount
Status readout
Accumulation amount readout
Trigger counter readout
Intelligent function
Function
External power supply interruption
detection function
Received light intensity waveform
acquisition function
Recipe selecting function
Function
Default recipe
Description
Measures an object.
Judges the measurement value when the upper/lower limit values are set.
Switches the state of laser between emission and stop.
Sets the measurement value obtained when the zero set is turned on to the reference value of measurement (zero).
The setting of the reference value of measurement is disabled when the zero set is turned off.
Holds the measurement value and the judgment output at a desired timing.
Resets the measurement value.
Searches the received light intensity of all measurement surfaces and sets the appropriate emitted light intensity
automatically.
Description
Copies the OUT setting between memory areas.
Changes the destination memory for saving the settings.
Copies the settings saved in a memory area to another memory area.
Initializes the settings in the memory area.
Saves the settings in all the memory areas.
Description
Stops buffering operation automatically.
Sets the buffering mode.
Selects the output data to be accumulated.
Loads data to be accumulated for a long time by being longer of the accumulation time interval.
Sets the accumulation amount of data.
Sets the conditions of trigger generation.
Delays the timing of data accumulation after trigger generation.
The data accumulation before trigger generation is displayed.
Sets the accumulation amount of data for each trigger generation.
Checks the status of accumulation operation.
Reads the accumulation amount of data.
Reads out the number of generated triggers.
Description
Detects an interruption of the external power supply.
Loads the received light intensity waveform to the buffer memory of the control module.
Description
Sets the parameters of the laser displacement sensor just by selecting the recipe (setting value of each function)
corresponding to the measurement object.
3 FUNCTION LIST