Chapter 1 Part Names - Mitsubishi Electric Melsec iQ-R Series User Manual

Laser displacement sensor control module for programmable controller
Hide thumbs Also See for Melsec iQ-R Series:
Table of Contents

Advertisement

1
PART NAMES
This chapter describes the part names of the control module.
(1)
(2)
(3)
+24V
(4)
24G
(5)
No.
Name
(1)
RUN LED
ERR LED
LASER A LED
LASER B LED
ALM1 LED
ALM2 LED
(2)
Sensor head A connector
(3)
Sensor head B connector
(4)
External power supply
terminal block
(5)
Production information
marking
The production information and firmware version can be checked by using the setting tool or engineering tool.
To check the firmware version by using the setting tool, check "Controller Ver" on the setting tool window.
For details, refer to the following.
 Laser Displacement Sensor MH11 SettingTool Version 2 Operating Manual
 MELSEC iQ-R Module Configuration Manual
Description
Indicates the operating status of the module.
• On: Normal operation
• Off: Module power supply interrupted
Indicates the error status of the module.
• On: Minor error ( MELSEC iQ-R Laser Displacement Sensor Control Module User's Manual (Application))
• Flashing: Moderate error ( MELSEC iQ-R Laser Displacement Sensor Control Module User's Manual
(Application))
• Off: Normal operation
• On: Sensor head A laser emission
• Off: Sensor head A laser stop
• On: Sensor head B laser emission
• Off: Sensor head B laser stop
• On: Alarm in OUT1 ( MELSEC iQ-R Laser Displacement Sensor Control Module User's Manual (Application))
• Flashing: Replacing sensor head ( Page 25 Procedure for sensor head replacement)
• Off: Normal operation
• On: Alarm in OUT2 ( MELSEC iQ-R Laser Displacement Sensor Control Module User's Manual (Application))
• Flashing: Replacing sensor head ( Page 25 Procedure for sensor head replacement)
• Off: Normal operation
The sensor head connected to this connector is recognized as sensor head A, to activate the control module.
The sensor head connected to this connector is recognized as sensor head B, to activate the control module.
A terminal block for connecting an external power supply cable to the control module
Shows the production information (16 digits) of the module.
1
1 PART NAMES
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r melsensor

Table of Contents