Download Print this page
ALLEN & HEATH W3MON-SLV2 Fitting Instructions
ALLEN & HEATH W3MON-SLV2 Fitting Instructions

ALLEN & HEATH W3MON-SLV2 Fitting Instructions

For allen & heath mixwizard wz3 12 mon sys-link

Advertisement

Quick Links

IT IS RECOMMENDED THAT THIS OPTION IS FITTED BY AN APPROVED ALLEN & HEATH SERVICE AGENT
SYS-LINK IN
SYS-LINK OUT
These are the instructions for fitting the SYS-LINK Version 2 console expander option to the MixWizard
3
WZ
12MON consoles. Two consoles, each with SYS-LINK V2 installed, may be linked together using a
single 37 way cable such that one becomes a channel expander (slave) to the other (master) providing a
total of 32 channels. This links all the mix buses and the PFL/AFL system. The cable is not supplied but
may be ordered separately or sourced elsewhere. Fitting the option requires removal of the rear connector
cover to access the internal assemblies, installation of a circuit card assembly and ribbon harness, and
some soldering. This work should be carried out by technically competent personnel.
For information on how to use SYS-LINK please refer to the Applications Note AP7008. Should further
assistance be required please contact Allen & Heath Technical Support.
Before Starting
Please see MOD information on last page then read these fitting instructions carefully before starting. For
trouble free installation and operation heed all the precautions noted.
unplugged and removed from its rack, plinth or other furniture before carrying out the work. Normal
workshop tools are required. These include Pozi (crosshead) and Torx (starhead) screwdrivers, and a fine
tipped soldering iron. Provide a suitably large, well lit work surface such as a service workshop bench. To
avoid damage to the cosmetics of the console ensure that the work surface is clean and clear of
obstructions. Allow enough time to carry out the work properly and test the results.
Check the Contents
IMPORTANT
:
Any changes or modifications
to the equipment not approved by Allen & Heath
could void the compliance of the equipment.
Whilst we believe the information in these
instructions to be reliable we do not assume
responsibility for inaccuracies. We also reserve
the right to make changes in the interest of
further product development.
Copyright© 2007 Allen & Heath Limited. All rights
reserved.
www.allen-heath.com
Fitting the SYS-LINK option cards
3
WZ
12MON SYS-LINK Option Fitting Instructions AP7007
Fitting Instructions for the W3MON-SLV2 Kit
The console must be fully
003-727-A x1 SYS-LINK IN circuit assembly
with power harness and fixing nuts.
003-727-B
x1
SYS-LINK
assembly with power harness and fixing nuts.
003-727-C X1 SYS-LINK IN SLAVE circuit
assembly.
AL6098 x1 short IDC ribbon harness
AL7005 x1 long IDC ribbon harness
AH0014
WIRE 7/0.2 PVC VIOLET
AP7008 x1 SYS-LINK V2 Applications Note.
This work should be carried out by
competent technical personnel only.
Disconnect the mains power cord before
opening the unit.
Take care not to damage the panels or
internal assemblies during fitting.
loose parts or dirt from entering the console
as this may cause equipment failure.
AP7007 issue 2
OUT
circuit
Prevent
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the W3MON-SLV2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ALLEN & HEATH W3MON-SLV2

  • Page 1 AP7007 issue 2 Fitting Instructions for the W3MON-SLV2 Kit IT IS RECOMMENDED THAT THIS OPTION IS FITTED BY AN APPROVED ALLEN & HEATH SERVICE AGENT SYS-LINK IN SYS-LINK OUT These are the instructions for fitting the SYS-LINK Version 2 console expander option to the MixWizard 12MON consoles.
  • Page 2 Step 1: Preparation Step 3: Open the connector panel Remove the two M3x6 Posi screws from each Ensure the console is powered off. side of the connector panel. Remove the six Disconnect the mains power lead and all M3x6 Pozi screws from the rear of the connector connected cables.
  • Page 3 Step 5: Fit the SYS-LINK cards to Step 8: Connect the IN card the console Take the harness of Mix 1, 2, 3 and 4 and plug one of the connectors into the slave PCB then Each SYS-LINK circuit card assembly is fixed to plug the slave PCB back on to Mix 1, 2, 3 and 4.
  • Page 4 Step 9: Connect the SYS-LINK power Step 12: Refit the base Both option cards get their power from the Check that all harnesses are correctly inserted console +15V and -15V rails available at solder and positioned, then carefully replace the base pads on the rear connector PCB.
  • Page 5 W312M SYS-Link MOD The SysLink PFL detect circuits depends on a THIS MOD DOSE NOT NEED TO BE FITTED good connection between the SysLink PCB’s IF THE MIX MASTERS ARE ISSUE 4 OR ABOVE. console chassis, following modification ensures that this can occur. Remove the Mix Master 3, 7, 11 PCB from the Slave console (the second last master PCB) Add a wire link between the chassis connection...