Pre-Installation Requirements
3-wire power supply cord
(not supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type
SRDT rated at 240 volt AC minimum,
30 amp, with 3 open end spade lug
connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see "Electrical connection
(non-Canada) - 3-wire cord" in Electrical
Installation section.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
4-wire power supply cord
(not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type
SRDT or DRT (as required) rated at 240
volt AC minimum, 30 amp, with 4 open end
spade lug connectors with upturned ends
or closed loop connectors and marked for
use with clothes dryers. For 4-wire cord
connection instructions see "Electrical
connection (non-Canada) - 4-wire cord" in
Electrical Installation section.
NOTE
Dryers manufactured for sale in Canada
have factory-installed, 4-wire power
supply cord (NEMA 14-30).
OUTLET RECEPTACLE - NEMA 14-30R
receptacle to be located so the power
supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
Electrical requirements for

gas dryer:

CIRCUIT - Individual, properly polarized
and grounded 15 amp. branch circuit
fused with 15 amp. time delay fuse or
circuit breaker.
POWER SUPPLY - 2-wire, with ground,
120 volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - Dryer is equipped
with 120 volt 3-wire power cord.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
Grounding type wall receptacle
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
Power cord with
3-prong grounded plug

Gas supply requirements

WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when
subjected to natural gas, causing gas leaks.
Use ONLY black iron, stainless steel, or
plastic-coated brass piping for gas supply.
1. The gas service to the dryer must
conform with local codes and
ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1/
11