10.5

Alarms and Relay Connections

Alarm Inputs
The camera provides seven alarm inputs. Each input can be activated by dry contact devices
such as pressure pads, passive infra-red detectors, door contacts, and similar devices. The
table below summarizes the size and distance wires.
Wire Size
AWG
22
18
Tab. 10.2: Alarm wire guide
You wire alarms either Normally Open (N.O.) or Normally Closed (N.C.), and must program the
alarm inputs N.O. (the default) or N.C. through the page Configuration.
The camera incorporates two types of alarms: Non-supervised and Supervised. In addition to
transmitting an alarm condition, a supervised alarm also transmits a tamper condition.
Depending on how the alarm is configured, a short or a break in the alarm's circuit can trigger
the tamper signal.
Configuring Supervised Alarms (inputs 1 and 2)
To configure Alarm 1 or 2 (pin 5 or 6) for supervision, you must install a 2.2 K end-of-line
resistor in the circuit. Then, you program the alarms, through Configuration, to either
Normally Open (N.O.) or Normally Closed (N.C.).
Notice!
Only Alarms 1 and 2 (pins 5 or 6) can be configured for supervision. Once a supervised alarm
is programmed, it does not need to be enabled to indicate a tamper condition.
Configuring a Normally Open Supervised Alarm
1.
2.
Figure 10.2: N.O.S. - Normally Open Supervised Connections
1
2
3.
Bosch Security Systems
Maximum Distance
mm
feet
0.644
500
1.024
800
Install a 2.2 K end-of-line resistor in the alarm circuit.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
2.2K
Dry Contact
Alarm 1 or 2 only (Pin 5 or 6)
From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.O. See the table below for contact and condition details.
meters
152.4
243.8
Installation Manual
Connection | en
3
Dome Connector
4
Ground (Pin 7)
33