WHOLE hoUSE VENTILATOR
PRODUCT MANUAL & INSTALLATION GUIDE
your home. Above a central hallway or at the top of a stairwell will provide the best airflow.
Make sure that there aren't any pipes, wires, rafters or air conditioning or heating ducts running through
the space where the GHOST will be installed. The GHOST can NOT be mounted vertically.
Make sure that you have adequate exhaust area out of your attic. This can be accomplished with
a combination of roof, ridge or gable end vents. The GHOST requires a minimum of 9 square feet of attic exhaust area.
If your home has an engineered roofing system, care should be taken that the GHOST will fit within the truss layout.
Tamarack Technologies, Inc.• 320 Main Street • Buzzards Bay, MA 02532
508-759-4660 • 800-222-5932 • Fax 508-759-6001 • www.tamtech.com
Serial Number
Date of Purchase
Point of Purchase
The serial number is located on the shipping carton
and on a label affixed to an insulated door.
When you have unpacked your GHOST
carefully you will find the following:
One (1) GHOST
One (1) White Metal Grille w/(6) Screws
One (1) Hand Held Remote Transmitter
One (1) Remote Receiver w/ line cord & interconnect cable
The GHOST should be installed in your attic in a central location within
GH.02