CENTRIFLOW 3D PLUG FAN GMPM, GMEB
INSTALLATION AND MAINTENANCE
FläktGroup
DC_9853GB_20180425_R0
PUR (A, B, C, D)
SLIDE IN ROTOR CASSETTE
CENTRIFLOW 3D PLUG FAN WITH PERMANENT
MAGNET AND ASYNCHRONOUS MOTOR
CONTENT
1. Importent information ........................................................................ 2
2. Saferty notes ......................................................................................... 2
3. Technical description ........................................................................ 3
4. Transport .................................................................................................4
5. Mounting instructions ........................................................................ 5
6. Commissioning .................................................................................... 6
7. Maingenance ......................................................................................... 8
8. Faults ..................................................................................................... 10
9. Spare parts ......................................................................................10
10. Distances ............................................................................................. 10
11. Air flow measurement ..................................................................10
12. Disposal of the product ................................................................10
13. Declaration of conformity .............................................................11
PAGE
Specifications are subject to alteration without notice

Advertisement

Table of Contents
loading

Summary of Contents for FläktGroup GMPM

  • Page 1: Table Of Contents

    CENTRIFLOW 3D PLUG FAN GMPM, GMEB PUR (A, B, C, D) SLIDE IN ROTOR CASSETTE INSTALLATION AND MAINTENANCE CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR CONTENT PAGE 1. Importent information ................ 2 2. Saferty notes ..................2 3.
  • Page 2: Importent Information

    Centriflow 3D GMPM, GMEB - Installation and Maintenance IMPORTANT INFORMATION, SAFETY NOTES 1. IMPORTANT INFORMATION 2. SAFETY NOTES FläktGroup fans comply with the requirements for health and This symbol is designed to point out all safety and safety of the EC Machinery Directive.
  • Page 3: Technical Description

    Only operate the fan up to the maximum permissible speed given in the information on the fan rating plate. 3.3 MOTORS Both AC- and PM-motors can be used with GMPM and GMEB plug fans. AC-motors are IEC-standard IE2 or IE3 motors. The motors are equipped with a thermistor and they are designed for a frequen- cy converter use.
  • Page 4: Transport

    Centriflow 3D GMPM, GMEB - Installation and Maintenance TRANSPORT 4 TRANSPORT There are three alternative places to attach the rear lifting hooks, which are to be used depending on the fan combination. 4.1 TRANSPORT INSPECTION Wherever possible, use holes on the motor bracket as shown in Check the fan immediately after you receive it and make sure that the picture below.
  • Page 5: Mounting Instructions

    Centriflow 3D GMPM, GMEB - Installation and Maintenance TRANSPORT, MOUNTING INSTRUCTIONS 5 MOUNTING INSTRUCTIONS 4.4.2 SIZES ≥080 The fan is to be lifted with four lifting chains/beams, two attached 5.1 INSTALLATION OF THE FAN to the front plate supports and two to the motor bracket. Lifting The fan is to be installed to a base frame using anti-vibration points are shown in the picture below.
  • Page 6 AHU to the inlet opening. 5.4. SAFETY REGULATIONS AND CE-MARKING The GMPM and GMEB fan is CE-marked as a Partly Completed Machinery and must not be put into service until the final machi- nery into which it is to be incorporated has been declared in con- formity with provisions of the Machinery Directive 2006/42/EC.
  • Page 7: Commissioning

    Centriflow 3D GMPM, GMEB - Installation and Maintenance COMMISSIONING 6 COMMISSIONING 6.1 SAFETY CHECKING • Rotate the shaft and check that the impeller can move freely. • Make sure that there are no foreign objects in the fan or in the ducting.
  • Page 8: Maingenance

    Centriflow 3D GMPM, GMEB - Installation and Maintenance MAINTENANCE 7. MAINTENANCE 7.3 REPLACING THE MOTOR AND THE IMPELLER The fan has to be disconnected and taken out from the unit be- 7.1 WARRANTY fore the motor can be replaced. A precondition of the warranty is that regular maintenance has been carried out.
  • Page 9 Centriflow 3D GMPM, GMEB - Installation and Maintenance MAINTENANCE 3. If needed, use an extraction tool to pull the impeller off the 7. Mount the impeller on the motor shaft. motor shaft. There is a groove in the impeller hub for the ex- 8.
  • Page 10: Faults

    Centriflow 3D GMPM, GMEB - Installation and Maintenance FAULTS, SPARE PARTS, DISTANCES, AIR FLOW MEASUREMENT DEVICE, DISPOSAL 8. FAULTS 11. AIR FLOW MEASUREMENT DEVICE If any faults occur during operation, they shall be repaired by The airflow sensor is used for measuring the airflow of the plug qualified maintenance personnel.
  • Page 11: Declaration Of Conformity

    Centriflow 3D GMPM, GMEB - Installation and Maintenance 13. DECLARATION OF CONFORMITY EC Declaration of incorporation for Partly Completed machinery Machinery Directive 2006/42/EC, Annex II, sub B Manufacturer: Fläkt Woods Oy Address: Kalevantie 39 FI-20520 Turku, Finland Name and address of the person authorised to compile the relevant technical documentation:...
  • Page 12 WWW.FLAKTGROUP.FI GMPM/GMEB 9853 A HISTORY OF INNOVATION AND RELIABILITY With more than a century of accumulated industry experience, FläktGroup is in a unique position to deliver energy efficient components and solutions for integrated performance, reliability and quality. With modern manufacturing technologies, precise deliveries and technical support, FläktGroup is your...