Recessed junction box installation (low voltage)
Warning
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local
and Provincial Codes.
Follow product label information and instructions.
Qualified Personnel must perform all servicing or relamping of
this product.
Before wiring to power supply and during servicing or
relamping, turn off power at fuse or circuit breaker before
service.
Round UPM mounting plate
with CamLock™ assembly
Universal mounting ring
1. Install standard 4" octagonal/round recessed
junction box in the final fixture location
according to designed lighting plan.
2. Pull branch circuit wiring necessary for
installation (By Others.)
B - K L I G H T I N G
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE.
REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
High Voltage
Hot Surface
The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause
an unsafe condition and void product warranty.
Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
Never operate the fixture with missing or damaged lens. Lens
must be cleaned on regular basis.
Energized lamp gets hot very quickly. Allow it to cool before
service.
UPM housing
3. Install universal mounting ring.
IMPORTANT!! Orientation of universal mounting ring will affect orientation of UPM! Take
note of mounting plate holes (indicated with arrows) on the universal ring holes to mount
UPM in correct orientation.
40429 Brickyard Drive • Madera, CA 93636 • USA
PM4RM ROUND CAMLOCK™
NEEDED
FOR
INSTALLATION:
By Others
(2) 3/4"and (1) 1/2"patented NPT knockouts*
Transformer
* UPM is covered in whole or in part by US patent #6,940,012
Horizontal
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
1/8" & 9/64" allen wrench
Wire connectors
Phillips screwdriver
Level
Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time. Use a
clean, dry, soft cloth to handle the lamp. Oil from skin may
damage the lamp and cause it to rupture.
Replace lamp only with correct wattage and type of lamp
marked on fixture label.
All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
UPM faceplate
Vertical
REVISION DATE
REFERENCE NUMBER
7-29-09
INS-1556

Advertisement

loading
Need help?

Need help?

Do you have a question about the PM4RM ROUND CAMLOCK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for B-K lighting PM4RM ROUND CAMLOCK

  • Page 1 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 2 PM4RM ROUND CAMLOCK™ Recessed junction box installation (low voltage) 4. Feed branch circuit wiring and lamp leads to 5. Feed branch circuit wiring into UPM housing. 7. If UPM housing is not level, remove UPM remote mounted fixture through mounting plate Install housing on CamLock™...
  • Page 3 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 4 READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS CERTIFIED TO CAN/CSA STANDARD C22.2 NO. 250 40429 Brickyard Drive • Madera, CA 93636 • USA REVISION DATE REFERENCE NUMBER B-K LIGHTING 559.438.5800 • FAX 559.438.5900 7-29-09 INS-1555 www.bklighting.com • info@bklighting.com...
  • Page 5 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 6 READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS CERTIFIED TO CAN/CSA STANDARD C22.2 NO. 250 40429 Brickyard Drive • Madera, CA 93636 • USA REVISION DATE REFERENCE NUMBER B-K LIGHTING 559.438.5800 • FAX 559.438.5900 7-29-09 INS-1557 www.bklighting.com • info@bklighting.com...

This manual is also suitable for:

Pm4rm tree strapPm4rm surface mount