Download Print this page

Fujitsu Waterstage Comfort 5 Operation Manual page 14

Air to water heat pump. split system
Hide thumbs

Advertisement

Table of Contents
Air to Water Heat Pump Split system
Line
Function
Holidays, heating circuit 2 (For the Holiday program is active, the heating mode should be on AUTO).
If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option).
651
Preselection
652
Period Start (Day / Month)
653
Period End (Day / Month)
658
Operating level
Heating adjustment, circuit 1
710
Comfort setpoint
712
Reduced setpoint
714
Frost protection setpoint
Cooling circuit 1
If the installation is fitted with the cooling kit (Only with the cooling kit option).
901
Operating mode
902
Comfort cooling setpoint
903
Reduced setpoint
Heating adjustment, Circuit 2
Only with the 2nd circuit kit option (If the installation consists of 2 heating circuits).
1010
Comfort setpoint
1012
Reduced setpoint
1014
Frost protection setpoint
Cooling circuit 2
If the installation is fitted with the cooling kit (Only with the cooling kit option).
1201
Operating mode
1202
Comfort cooling setpoint
1203
Reduced setpoint
Domestic hot water
If the installation is fitted with the DHW kit.
1600
Operating mode
1610
Nominal setpoint
The backup electrical system is required to reach this level.
1612
Reduced setting
Swimming pool (Only with swimming pool kit option)
2055
Setpoint solar heating
2056
Setpoint source heating
- 14 -
Setting range
or display
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection, Reduced
Reduced setpoint...
Comfort setpoint maximum
Frost protection setpoint...
Comfort setpoint
4 °C... Reduced setpoint
Protection, Automatic, Reduced,
Comfort
17... 40 °C
5... 40°C
Reduced setpoint...
Comfort setpoint maximum
Frost protection setpoint...
Comfort setpoint
4 °C... Reduced setpoint
Protection, Automatic, Reduced,
Comfort
17... 40 °C
5... 40°C
Off, On, Eco
Reduced setpoint (line 1612)...
65 °C
8 °C...
Nominal setting (line 1610)
8... 80 °C
8... 35 °C
Setting
Basic
setting
increment
Period 1
1
1
Frost
protection
0,5 °C
20 °C
0,5 °C
19 °C
0,5 °C
8 °C
Protection
0,5 °C
24 °C
26 °C
0,5 °C
20 °C
0,5 °C
19 °C
0,5 °C
8 °C
Protection
0,5 °C
24 °C
26 °C
On
55 °C
1
1
40 °C
26 °C
22 °C
Operation manual "1534 - EN"

Hide quick links:

Advertisement

Table of Contents
loading