Technical Data - AEG DBS 5573 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 41
When you have finished
• Now you can start ironing. Always turn the temperature
control to "MIN" after use and remove the mains plug
(the control lamp in the handle goes off).
• Remove the mains plug from the socket. The tank illumi-
nation goes out.
• Empty the water tank.
• Allow the device to cool down before you put it away.
Anti-scale filter
Your steam iron station is fitted with an anti-scale filter. The
anti-scale filter cartridge becomes spent after filtering ap-
proximately 18 litres of water, depending on the hardness
of your water. It then loses its effectiveness and must be
replaced.
• Turn off the appliance.
• Disconnect the mains plug from the mains.
• Remove the water tank.
• Remove the anti-scale filter cartridge.
• Fill the tank up to the maximum mark. Do not overfill!
• Insert a new anti-scale filter cartridge.
• Before turning on the appliance, wait a few minutes until
the new filter cartridge is saturated with water.
NOTE:
If you do not have a new anti-scale filter cartridge, you can
still iron with the used cartridge and distilled water.
Cleaning
WARNING:
• Always remove the mains lead before cleaning!
• Wait until the machine has cooled down completely.
• Under no circumstances should you immerse the
device in water for cleaning purposes. Otherwise this
might result in an electric shock or fire.
CAUTION:
• Do not use a wire brush or any abrasive items.
• Do not use any acidic or abrasive detergents.
• Children shall not perform cleaning without supervision.
• Clean the casing with a slightly damp cloth.
• Clean the sole plate and the rest with a slightly damp
cloth.
• Any residual water can remain in the water tank, but
should be poured out if it has been in the tank for a
prolonged period.
Troubleshooting
Fault
Possible Cause
Device does not
Faulty mains
work
socket
The thermostat
is set to the posi-
tion "MIN"
Loud noises
The tank is
during steam
empty
operation
The device
Is the electric cir-
suddenly stops
cuit overloaded?
working during
operation
The tank illumi-
The lime filter
nation does not
cartridge is mis-
light after heat-
sion or has not
ing and no steam
been set cor-
is generated
rectly.
The water tank
has not been in-
stalled correctly.

Technical Data

Model: ................................................................................DBS 5573
Power supply: .......................................................230 V~, 50/60 Hz
Power consumption:............................................................ 2200 W
Protection class: .................................................................................I
Maximum filling quantity of the water tank: ...................1.0 Litre
Net weight: ..............................................................approx. 3.25 kg
Subject to technical changes without prior notice!
This device has been tested according to all relevant cur-rent
CE guidelines, such as electromagnetic compatibility and low
voltage directives, and has been constructed in accordance
with the latest safety regulations.
English
45
Remedy
Try another
socket
Set it to the de-
sired position.
Check the tank
Check the house
fuse
Check the posi-
tion of the lime
filter cartridge.
A "click"
confirms that
the water tank
has been set
correctly.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents