11.7.3. Check Table for RF part
No.
Item
1a Link confirmation Normal
1b Link confirmation TX Test
1c Link confirmation RX Test
2
Control signal confirmation
3
X'tal Frequency
confirmation(*5)
4
TX Power confirmation
5
RX Sensitivity confirmation
Note:
(*1) TEST MODE (P.37)
(*2) RF-DSP interface signal wave form (P.35)
(*3) CIRCUIT BOARD (BASE UNIT) Component View (P.89)
(*4) CIRCUIT BOARD (HANDSET) Component View (P.93)
(*5) X801 (Base Unit), X201 (Handset) Check (P.44)
BU checking
1. Re-resister HS Regular Unit (working) to BU.
2. Press [Talk] key of the HS Regular Unit to
establish link.
1. Re-resister HS Regular Unit (working) to BU.
2. Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
3. Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
4. Press [1] key of HS Regular Unit to establish link
about 5m away from BU.
5. Press [1] key of HS Regular Unit to set RSSI
mode, and press [2] key to set RX Gain Low.
6. Confirm the value of RSSI in LCD of HS Regular
Unit is more than "e0(hex)".
1. Re-resister HS Regular Unit (working) to BU.
2. Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
3. Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
4. Press [1] key of HS Regular Unit to establish link
about 5m away from BU.
5. Press [REC] key of BU to set RSSI mode, and
press [GREETING CHECK] key to set RX Gain
Low.
6. Confirm the value of RSSI in LCD of BU is more
than "e0(hex)".
1. Set TX Burst mode.(*1)
2. Check DSP interface.(*2)
1. Adjust X'tal mode.(*1)
2. Check X´tal Frequency.
(13.824000MHz±100Hz)
1. Set BU to TX Burst mode at 45ch. (*1)
(TX Power:High)
2. Set HS Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3. Place HS Regular Unit about 5m away from BU.
4. Confirm RSSI of HS Regular Unit is more than
1.75V by Oscilloscope. (*4)
1. Set BU to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2. Set HS Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power:High)
3. Place HS Regular Unit about 5m away from BU.
4. Confirm RSSI of BU is more than 1.75V by
Oscilloscope.(*3)
1. Re-resister HS to BU of Regular Unit (working).
2. Press [Talk] key of the HS to establish link.
1. Re-resister HS to BU Regular Unit (working).
2. Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:Low)
3. Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
4. Press [1] key of HS to establish link about 5m
away from BU of Regular Unit.
5. Press [REC] key of BU Regular Unit to set RSSI
mode, and press [GREETING CHECK] key to set
RX Gain Low.
6. Confirm the value of RSSI in LCD of BU Regular
Unit is more than "e0(hex)".
1. Re-resister HS to BU of Regular Unit (working).
2. Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power:High / RX Gain:High)
3. Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power:Low / RX Gain:Low)
4. Press [1] key of HS to establish link about 5m
away from BU Regular Unit.
5. Press [1] key of HS to set RSSI mode, and press
[2] key to set RX Gain Low.
6. Confirm the value of RSSI in LCD of HS is more
than "e0(hex)".
1. Set TX Burst mode.(*1)
2. Check DSP interface.(*2)
1. Adjust X'tal mode.(*1)
2. Check X´tal Frequency.
(13.824000MHz±100Hz)
1. Set HS to TX Burst mode at 45ch. (*1)
(TX Power:High)
2. Set BU Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3. Place HS about 5m away from BU Regular Unit.
4. Confirm RSSI of BU Regular Unit is more than
1.75V by Oscilloscope.(*3)
1. Set HS to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2. Set BU Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power:High)
3. Place HS about 5m away from BU Regular Unit.
4. Confirm RSSI of HS is more than 1.75V by
Oscilloscope.(*4)
34