Siemens RUGGEDCOM RSG920P Installation Manual page 52

Hide thumbs Also See for RUGGEDCOM RSG920P:
Table of Contents

Advertisement

Chapter 6
Certification
Test
IEC 60255-5
a
Severity level set by Siemens.
b
Common mode tests performed on the signal port shield.
c
For IEC 61850-3 compliance when using Power-over-Ethernet (PoE), an IEC 61850-3 compliant PoE power supply must be installed in the vicinity of the device
with power cabling no longer than 3 meters (118 in).
EMC Immunity Type Tests per IEEE 1613
NOTE
The RUGGEDCOM RSG920P meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires
error-free and interrupted communications.
Electrostatic Discharge (ESD)
Radiated Radio Frequency Immunity (RFI)
Burst (Electrical Fast Transient)
Damped Oscillatory Wave
Dielectric Strength
Damped Oscillatory Magnetic Field
42
Description
Dielectric Strength
HV Impulse
Description
Enclosure Contact
Enclosure Contact
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Port
AC Power Port
Signal Ports
DC Power Port
AC Power Port
Enclosure Ports
Signal Ports
2 kV (Fail-Safe Relay Output)
DC Power Ports
AC Power Ports
Signal Ports
5 kV (Fail-Safe Relay Output)
DC Power Ports
AC Power Ports
Test Levels
±8 kV
±15 kV
35 V/m (80% Modulation)
±4 kV at 2.5 kHz
±4 kV
±4 kV
±4 kV
2.5 kV Common Mode at 1 MHz
2.5 kV Common and
Differential Mode at 1 MHz
2.5 kV Common and
Differential Mode at 1 MHz
2 kV
2 kV
2 kV
100 A/m (Peak) at 100 kHz and 1 MHz
Installation Guide
Test Levels
100% for 0.05 s
2 kV
2 kV
5 kV
5 kV
Severity Levels
EMC and Environmental Type Tests
RUGGEDCOM RSG920P
Severity Levels
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents