Chapter 2
Installing the Device
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to terminals for DC
power. Damage to the power supply may occur.
1.
Secure a European-style terminal block (or Euroblock) to the terminal.
2.
Connect the live/positive wire from the power source to the live/positive (L/+) terminal on the terminal block.
Figure 10: Terminal Block Wiring
1. Main Power Terminal Block    2. Neutral/Negative (N/-) Terminal    3. Chassis Ground Terminal    4. Live/Positive (L/+) Terminal
3.
Connect the neutral/negative wire from the power source to the neutral/negative (N/-) terminal on the
terminal block.
4.
Connect the ground wire to the chassis ground terminal on the device.
Section 2.8.2

Connecting Low DC Power

To connect a single or dual power sources to the low DC power supply, do the following:
IMPORTANT!
When connecting two external power sources, if the first external power source has a voltage lower
than 33 VDC, the second power source must have a voltage lower than 33 VDC as well. Similarly, if the
first power source has a voltage higher than 36 VDC, the second power source must have a voltage
higher than 36 VDC.
1.
Connect the positive wire from the power source to the positive terminal on the terminal block.