5.25" floppy or Irwin FTD
Cabling
The 5.25" floppy and Irwin FTD drives supplied by Apricot
come complete with a suitable signal cable. The signal
cable must be connected between the signal connector on
the rear of the drive, and the socket marked PL38 on the
motherboard.
Use the label on the inside of the system unit cover to
identify PL38.
Warning
Check the label on the inside of the system unit cover to
make sure you are using the correct connector. Failure to
do so may damage the drive or the system board.
Configuration
The only configuration on these drives is via the drive
select jumpers at the rear of the drive. The jumpers should
be set to drive select 1 (DS1).
SLCD CD-ROM
Cabling
The Apricot SLCD CD-ROM drive is supplied with two
signal cables. The wide data cable must be connected
between the rear of the SLCD CD-ROM drive and PL36 on
the motherboard. The narrow audio cable must be
connected between the drive and PL4 on the motherboard.
Use the label on the inside of the system unit cover to
identify PL36 and PL4.
Warning
Check the label on the inside of the system unit cover to
make sure you are using the correct connectors. Failure to
do so may damage the drive or the system board.
Note
If there is an expansion card installed in the bottom slot you
will have to remove it in order to access PL4.