Logix™ Chlorine Generator (Check Salt Light)
Installation Instructions
The Logix 740C/742C and 760C/762C controls
have the capability to command a device
Chlorine Generator Outlet (740C/742C and 760C/762C versions)
for chlorine production (optional) to disinfect the
resin bed at every regeneration.
There is a check salt light which indicates
when the salt finishes.
Potassium chloride or sodium
chloride may be used. Installing the chlorine
generator is simple.
Step 1
Back of Logix Control
Remove the Logix control from the valve and
disconnect power.
Step 2
Connect the chord to the plug
Refill Controller
on the back of the Logix control
Check Salt Light
at the connection labeled "Chlorine Generator
Outlet 740C/742C and 760C/762C."
Step 3
Remove the existing refill controller
from the valve and replace it with the chlorine
Injector and Cap
generator refill flow control. See the illustrations
to the right for the location of the refill controller.
255 Valve Identification
Step 4
Insert the large connector of the chlorine
generator chord to the end of the refill flow
control. Press it in firmly to make sure there is
good contact.
Check Salt Light
Step 5
Reconnect power to the Logix Control and
reinstall the control to the valve.
No programming is necessary for the chlorine
generator to work properly. After the chlorine
Injector and cap
generator senses regenerant for the first time it
Refill Controller
will be functional. There is a check salt light on
Performa Valve Identification
the front of the Logix control that will illuminate
when there is no regenerant present during the
regenerant draw.