8.7 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
The burner flame may be
extinguished by an air flow,
if the removable panel is not
installed. The air flow may
occur when you open or
close the cabinet door or
drawer.
Kitchen unit with door
60 mm
B

9. TECHNICAL DATA

9.1 Hob dimensions
Width
Depth
9.2 Bypass diameters
BURNER
Rapid
Semi-rapid
Auxiliary
9.3 Other technical data
TOTAL POWER:
Electric supply:
30 mm
min 20 mm
A
(max 150 mm)
Gas original:
220-240 V ~ 50/60 Hz
A. Removable panel
B. Space for connections
Kitchen unit with drawer
A
60 mm
B
A. Removable panel
B. Space for connections
C. Drawer
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
595 mm
525 mm
Ø BYPASS 1/100 mm
56
42
34
G20 (2H) 20 mbar = 7,9 kW
ENGLISH
15
30 mm
min 20 mm
(max 150 mm)
C