Electrical installation

NOTE
Electrical installation and service must be car-
ried out under the supervision of a qualified
electrician, and in accordance with applicable
electrical safety regulations.
SENSORS
VPB 200 and VPB 300 can be supplemented with up to
two hot water sensors, one for display and one for
control. The display sensor is positioned in the sub-
merged tube for the display sensor (UA1) and the control
sensor is positioned in the submerged tube for the
control sensor UA2. In cases where it is only possible
to connect one sensor, use the submerged tube for the
control sensor (UA2).
VPBS 300 can also be supplemented with a solar sensor.
This is placed in a submerged tube for the solar sensor
(UA3).
Use the sensors provided with the heat pump (or other
heat source). When no heat sensors have been provided
these must be ordered from the manufacturer of the
heat source.
The figure shows VPBS 300.
14
Chapter 3 | For the Installer
DIRECT-CURRENT ANODE
VPB/VPBS Enamel is equipped with direct-current anode
and enclosed with potentiostat from the factory. The
anode cable (W1) is installed in the anode from the
factory and only needs to be connected to the potentio-
stat.
1.
Route the anode cable (W1) along the docking pipe,
supply line (XL8).
Connect the anode cable (W1) to the potentiostat.
2.
Connect the potentiostat to a suitable 230 V wall
3.
socket.
NOTE
The cable between the potentiostat and the
anode must either be extended or shortened.
XL8
W1
UA1
The figure shows VPB 200 E.
UA2
UA3
W1