Sun Microsystems SG-XPCIE1FC-EM8-Z Installation Manual
Sun Microsystems SG-XPCIE1FC-EM8-Z Installation Manual

Sun Microsystems SG-XPCIE1FC-EM8-Z Installation Manual

Storagetek 8 gb fc pciexpress hba, emulex
Hide thumbs Also See for SG-XPCIE1FC-EM8-Z:

Advertisement

Quick Links

Sun StorageTek
8 Gb FC PCI-
Express HBA, Emulex Installation
Guide
For HBA Models SG-XPCIE1FC-EM8-Z and
SG-XPCIE2FC-EM8-Z
Sun Microsystems, Inc.
www.sun.com
Part No. 820-5465-12
December 2008, Revision A
Submit comments about this document at: http://www.sun.com/hwdocs/feedback

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG-XPCIE1FC-EM8-Z and is the answer not in the manual?

Questions and answers

Summary of Contents for Sun Microsystems SG-XPCIE1FC-EM8-Z

  • Page 1 ™ Sun StorageTek 8 Gb FC PCI- Express HBA, Emulex Installation Guide For HBA Models SG-XPCIE1FC-EM8-Z and SG-XPCIE2FC-EM8-Z Sun Microsystems, Inc. www.sun.com Part No. 820-5465-12 December 2008, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
  • Page 2 Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la limitation, ces droits de propriété...
  • Page 3: Table Of Contents

    Contents Declaration of Conformity v Regulatory Compliance Statements vii Safety Agency Compliance Statements xi Preface xxiii HBA Overview 1 Kit Contents 1 HBA Features and Specifications 2 Operating System and Technology Requirements 3 System Interoperability 4 Host Platform Support 4 Storage Support 5 Array Support 6 System Support 6...
  • Page 4 Observing ESD and Handling Precautions 9 Installing the Hardware 10 ▼ To Install the HBA 10 ▼ To Connect the Optical Cable 14 ▼ To Apply Power 15 ▼ (LED) Status 15 Testing the Installation 17 ▼ To Verify Proper Installation (for the Solaris OS) 17 ▼...
  • Page 5: Supplementary Information

    This product was tested and complies with all the requirements for the CE Mark. This equipment complies with the Restriction of Hazardous Substances (RoHS) directive 2002/95/EC. P001219 Sun StorageTek™ Enterprise 8Gb FC PCI-Express Single and Dual Port Host Bus Adapter (SG-XPCIE1FC-EM8-Z, SG-XPCIE2FC-EM8-Z) Class A Pass Pass...
  • Page 6 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008 DATE Donald Cameron Program Manager/Quality Systems Sun Microsystems Scotland, Limited Blackness Road, Phase I, Main Bldg. Springfield, EH49 7LR Scotland, United Kingdom Tel: +44 1 506 672 539...
  • Page 7: Fcc Class A Notice

    Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
  • Page 8: Bsmi Class A Notice

    BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A” on the product’s compliance label.
  • Page 9 Regulatory Compliance Statements...
  • Page 10 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008...
  • Page 11: Safety Precautions

    The On/Standby switch is in the standby position. Modifications to Equipment Do not make mechanical or electrical modifications to the equipment. Sun Microsystems is not responsible for regulatory compliance of a modified Sun product. Placement of a Sun Product Caution –...
  • Page 12: Battery Warning

    products). To reduce the risk of electric shock, do not plug Sun products into any other type of power system. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building.
  • Page 13: System Unit Cover

    System Unit Cover You must remove the cover of your Sun computer system unit to add cards, memory, or internal storage devices. Be sure to replace the cover before powering on your computer system. Caution – Do not operate Sun products without the cover in place.
  • Page 14 Modification du matériel N'apportez aucune modification mécanique ou électrique au matériel. Sun Microsystems décline toute responsabilité quant à la non-conformité éventuelle d'un produit Sun modifié. Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008 Positionnement d’un produit Sun...
  • Page 15 utilisés avec des ordinateurs. N'utilisez jamais de cordon d'alimentation à usage domestique avec les produits Sun. L'avertissement suivant s'applique uniquement aux systèmes équipés d'un interrupteur Veille: Attention – L'interrupteur d'alimentation de ce produit fonctionne uniquement comme un dispositif de mise en veille. Le cordon d'alimentation constitue le moyen principal de déconnexion de l'alimentation pour le système.
  • Page 16 Wartezustand – Der Ein-/Standby-Netz- schalter befindet sich in der Standby-Position. Modifikationen des Geräts Nehmen Sie keine elektrischen oder mechanischen Gerätemodifikationen vor. Sun Microsystems ist für die Einhaltung der Sicherheitsvorschriften von modifizierten Sun-Produkten nicht haftbar. Aufstellung von Sun-Geräten Achtung – Geräteöffnungen Ihres Sun- Produkts dürfen nicht blockiert oder...
  • Page 17: Anschluss Des Netzkabels

    tung dieser Richtlinien kann Überhitzung verursachen und die Zuverlässigkeit Ihres Sun-Geräts beeinträchtigen. Lautstärke Produkt: Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Gemäß den Vorgaben in der Norm ISO 7779 beträgt der Geräuschpegel dieses Geräts in Abhängigkeit vom Arbeitsplatz unter 70 db(A). Gemäß...
  • Page 18 Normativas de seguridad Lea esta sección antes de realizar cualquier operación. En ella se explican las medidas de seguridad que debe tomar al instalar un producto de Sun Microsystems. Medidas de seguridad Para su protección, tome las medidas de seguridad siguientes durante la instalación del equipo:...
  • Page 19: Nivel De Ruido

    Modificaciones en el equipo No realice modificaciones de tipo mecánico ni eléctrico en el equipo. Sun Microsystems no se hace responsable del cumplimiento de normativas en caso de que un producto Sun se haya modificado.
  • Page 20 de tierra situada cerca del sistema y de fácil acceso. No conecte el cable de alimentación si la unidad de alimentación no se encuentra en el bastidor del sistema. La siguiente medida solamente se aplica a aquellos dispositivos que dispongan de varios cables de alimentación: Precaución –...
  • Page 21 Dispositivos de CD y DVD La siguiente medida se aplica a los dispositivos de CD y DVD, así como a otros dispositivos ópticos: Precaución – La utilización de controles, ajustes o procedimientos distintos a los aquí especificados puede dar lugar a niveles de radiación peligrosos.
  • Page 22 xxii Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008...
  • Page 23: How This Book Is Organized

    Preface This installation guide describes how to install and remove the single and dual port Sun StorageTek™ 8 Gigabit (Gb) Fibre Channel (FC) PCI-Express module host bus adapter (HBA). It also explains how to install the driver and any other utilities required by the HBA.
  • Page 24: Shell Prompts

    Chapter 4 contains known issues with the HBA. Using UNIX Commands This document might not contain information about basic UNIX procedures such as shutting down the system, booting the system, and configuring devices. Refer to the following for this information: Software documentation that you received with your system ■...
  • Page 25: Typographic Conventions

    Typographic Conventions Typeface Meaning The names of commands, files, AaBbCc123 and directories; on-screen computer output. What you type, when contrasted AaBbCc123 with on-screen computer output. AaBbCc123 Book titles, new words or terms, words to be emphasized. Replace command-line variables with real names or values. Note –...
  • Page 26: Third-Party Web Sites

    Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources.
  • Page 27: Hba Overview

    C H A P T E R HBA Overview This chapter provides a basic overview of the single and dual port Sun StorageTek™ 8 Gb Fibre Channel (FC) PCI-Express host bus adapter (HBA), Emulex (referred to as Sun StorageTek 8 Gb FC PCI-Express HBA in this document), which uses Emulex technology.
  • Page 28: Hba Features And Specifications

    HBA Features and Specifications The Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex (single port: SG-XPCIE1FC- EM8-Z, dual port: SG-XPCIE2FC-EM8-Z) consists of a single-wide, FC bus expansion board. The board interfaces a four- or eight-lane PCI-Express bus, with the four or eight lanes supporting one or two Fibre Channel (FC) optical media ports.
  • Page 29: Operating System And Technology Requirements

    HBA Features and Specifications TABLE 1-1 Feature (Continued) Description (Continued) 2 Gb/s: 500 meters using 50/125 µm core OM3 fiber Maximum FC cable length 4 Gb/s: 380 meters using 50/125 µm core OM3 fiber 8 Gb/s: 150 meters using 50/125 µm core OM3 fiber LED indicators Two LEDs per port (yellow and green) on the front panel as status indicators.
  • Page 30: System Interoperability

    Supported Operating System/Technology Versions (Continued) TABLE 1-2 Operating System/Technology Microsoft Windows OS Enterprise and Standard Editions WHQL Certified, MS Windows MPIO Microsoft Windows OS Enterprise and Standard Editions WHQL Certified, MS Windows MPIO VMware Technology System Interoperability This section provides information about selected platforms and storage that are compatible with the heterogeneous FC network design of the HBA.
  • Page 31: Storage Support

    Platform Support (Continued) TABLE 1-3 Platform (Continued) Sun SPARC Enterprise M4000 Sun SPARC Enterprise M5000 Sun SPARC Enterprise M8000 Sun SPARC Enterprise M9000-32 Sun SPARC Enterprise M9000-64 Sun Fire™ V445 Sun Fire V245 Sun Ultra U45 Sun x64 AMD Servers Sun Fire X4100M2 Sun Fire X4200M2 Sun Fire X4600...
  • Page 32: Array Support

    Array Support The HBA is supported by the following arrays: Sun StorageTek 2540 ■ Sun StorageTek 6140 ■ Sun StorageTek 6540 ■ System Support The HBA is supported by the following systems: Sun StorageTek 9990 ■ Sun StorageTek 9980/9985 ■ Sun StorageTek 9970 ■...
  • Page 33: Environmental Requirements

    Brocade 200E switch ■ Brocade 300 switch ■ Brocade SW4100 switch ■ Brocade SW4900 switch ■ Brocade SW5000 switch ■ Brocade SW5100 switch ■ Brocade SW5300 switch ■ Brocade SW7500 switch ■ Cisco MDS9124 24-port multilayer fabric switch ■ Cisco MDS 9134 multilayer fabric switch ■...
  • Page 34 HBA Environmental Requirements TABLE 1-4 Specification Operating Altitude 3200m Vibration 0.20G in all axes swept for 5-500 Hz sine Shock 5G, 11 ms half-sine Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008 Non-Operating 12,200m 1.0G in all axes 5-500-5 Hz sine 30G, 11 ms half-sine...
  • Page 35: Hardware Installation And Removal

    C H A P T E R Hardware Installation and Removal This chapter describes the tasks required to install and remove the HBA. Refer to your system installation or service manual for detailed instructions. This chapter contains the following topics: “Observing ESD and Handling Precautions”...
  • Page 36: To Apply Power

    Hold the HBA by the edge of the PCB, not by the connectors. ■ Place the HBA on a properly grounded antistatic work surface pad when it is out ■ of its protective antistatic bag. Installing the Hardware The hardware installation process involves the following general steps, as described in these sections: “To Install the HBA”...
  • Page 37 a. Remove the transceiver from its cage assembly (see bail (handle) out and down to release the latch and gently pull the transceiver out of its housing. Do not force it. After the latch is released, the transceiver slides out easily.. Caution –...
  • Page 38 b. Observing ESD precautions, store the transceiver in an ESD-safe place. c. Remove the mounting bracket screws from the top of the HBA. Removing the Bracket Mounting Screws FIGURE 2-3 d. Remove the bracket and store it for future use. e.
  • Page 39: To Connect The Optical Cable

    9. Replace the computer case and tighten the case screws. The HBA is now installed in the computer and is ready for media attachment. ▼ To Connect the Optical Cable Note – The HBA does not allow normal data transmission on an optical link unless it is connected to another similar or compatible Fibre Channel product (that is, multimode to multimode).
  • Page 40: To Apply Power

    Attaching the Optical Cable FIGURE 2-4 2. Connect the other end of the cable to the FC device. After the optical cable is connected to the HBA, you can power on the system. ▼ To Apply Power 1. Verify that the HBA is securely installed in the system. 2.
  • Page 41: Led) Status

    LEDs FIGURE 2-5 Figure Legend Port 0 LEDs Port 1 LEDs 4. Observe the light-emitting diode (LED) status for the power-on self test (POST) results as shown in TABLE 2-2 LED Status TABLE 2-2 Green LED Yellow LED Slow Blink Fast Blink Flashing 2 Fast Blinks...
  • Page 42: To Verify Proper Installation (For The Solaris Os)

    The HBA can be identified in the output by looking for the SUNW,emlxs@n and SUNW,emlxs@n,1 node names, where n is usually a single-digit number from 0 to 9. In this example, there are two dual port (SG-XPCIE2FC-EM8-Z) and one single port (SG-XPCIE1FC-EM8-Z) HBAs installed. {0} ok show-devs /pci@7c0/pci@0...
  • Page 43 (continued) /pci@7c0/pci@0/pci@9/SUNW,emlxs@0,1/fp@0,0/disk /pci@7c0/pci@0/pci@9/SUNW,emlxs@0/fp@0,0 /pci@7c0/pci@0/pci@9/SUNW,emlxs@0/fp@0,0/disk /pci@7c0/pci@0/pci@8/SUNW,emlxs@0 /pci@7c0/pci@0/pci@8/SUNW,emlxs@0/fp@0,0 /pci@7c0/pci@0/pci@8/SUNW,emlxs@0/fp@0,0/tape/pci@7c0/pci@0/pci@8 /SUNW,emlxs@0/fp@0,0/disk /pci@7c0/pci@0/pci@2/network@0,1 /pci@7c0/pci@0/pci@2/network@0 /pci@7c0/pci@0/pci@1/pci@0,2 /pci@7c0/pci@0/pci@1/pci@0 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@2,1 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@2 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1,1 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@2,1/fp@0,0 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@2,1/fp@0,0/disk /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@2/fp@0,0 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@2/fp@0,0/disk /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1,1/fp@0,0 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1,1/fp@0,0/tape /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1,1/fp@0,0/disk /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1/fp@0,0 /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1/fp@0,0/tape /pci@7c0/pci@0/pci@1/pci@0,2/SUNW,emlxs@1/fp@0,0/disk /pci@7c0/pci@0/pci@1/pci@0/ide@8 /pci@7c0/pci@0/pci@1/pci@0/usb@6 /pci@7c0/pci@0/pci@1/pci@0/usb@5 /pci@7c0/pci@0/pci@1/pci@0/isa@2 /pci@7c0/pci@0/pci@1/pci@0/ide@8/cdrom /pci@7c0/pci@0/pci@1/pci@0/ide@8/disk /pci@7c0/pci@0/pci@1/pci@0/usb@6/hub@1 /pci@7c0/pci@0/pci@1/pci@0/isa@2/serial@0,3f8 /pci@780/pci@0 /pci@780/pci@0/pci@9 /pci@780/pci@0/pci@8 /pci@780/pci@0/pci@2 /pci@780/pci@0/pci@1 /pci@780/pci@0/pci@9/scsi@0 Chapter 2 Hardware Installation and Removal...
  • Page 44 (continued) /pci@780/pci@0/pci@9/scsi@0/disk /pci@780/pci@0/pci@9/scsi@0/tape /pci@780/pci@0/pci@8/SUNW,emlxs@0,1 /pci@780/pci@0/pci@8/SUNW,emlxs@0 /pci@780/pci@0/pci@8/SUNW,emlxs@0,1/fp@0,0 /pci@780/pci@0/pci@8/SUNW,emlxs@0,1/fp@0,0/tape /pci@780/pci@0/pci@8/SUNW,emlxs@0,1/fp@0,0/disk /pci@780/pci@0/pci@8/SUNW,emlxs@0/fp@0,0 /pci@780/pci@0/pci@8/SUNW,emlxs@0/fp@0,0/tape /pci@780/pci@0/pci@8/SUNW,emlxs@0/fp@0,0/disk /pci@780/pci@0/pci@1/network@0,1 /pci@780/pci@0/pci@1/network@0 /packages/SUNW,builtin-drivers {c} ok 2. To positively identify the port as a Sun StorageTek 8 Gb FC port, use the cd command to change to the SUNW,emlxs@n directories, and use the .properties command.
  • Page 45 In this example, the .properties command output displays the properties of the two ports in a dual port HBA. ok cd /pci@780/pci@0/pci@8/SUNW,emlxs@0 {c} ok .properties assigned-addresses 00002000 82060018 00000000 00304000 00000000 00004000 81060020 00000000 00000000 00000000 00000100 82060030 00000000 00340000 00000000 00040000 port_wwn node_wwn alternate-reg...
  • Page 46: To Verify Attached Storage (For The Solaris Os)

    assigned-addresses 00002000 port_wwn node_wwn alternate-reg compatible clock-frequency #size-cells #address-cells copyright model name device_type manufacturer fcode-version fcode-rom-offset devsel-speed class-code interrupts latency-timer cache-line-size max-latency min-grant subsystem-id subsystem-vendor-id revision-id device-id vendor-id {0} ok ▼ To Verify Attached Storage (for the Solaris OS) ● If online storage is connected to the HBA, use the apply show-children command to list the attached storage.
  • Page 47 Note – You might need to use the reset-all command before using the apply show-children command. In the example that follows, four SANS with 14 to 16 drives each and an FC tape drive are attached to the two ports or a dual-port HBA. {14} ok show-children Device PortID 10600...
  • Page 48 (continued) Device PortID 20600 Device PortID 20700 Device PortID 20900 {14} ok Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008 WWPN 200600a0b8220345 Disk CSM100_R_FC Disk CSM100_R_FC Disk CSM100_R_FC Disk CSM100_R_FC Disk CSM100_R_FC Disk CSM100_R_FC Disk CSM100_R_FC Disk CSM100_R_FC...
  • Page 49: Replacing The Sfp+ Unit On The Hba

    Replacing the SFP+ Unit on the HBA The Small Form Factor Pluggable (SFP+) optics unit on this card is considered a part of the card, NOT as a separate field replaceable unit (FRU). Therefore, in the event that the SFP+ unit malfunctions, you must return the entire card in order to receive a replacement SFP+ unit.
  • Page 50 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008...
  • Page 51: Driver Software For The Solaris Os

    C H A P T E R HBA Software Installation After you have completed the hardware installation and powered on the system, follow the instructions in this chapter for your operating system to install the HBA driver and any other utilities that are required. This chapter contains the following topics: “Driver Software for the Solaris OS”...
  • Page 52: Installing Software For The Red Hat And Suse Linux Oses

    The driver and utilities are available for download at the Emulex support site for Sun Microsystems. ▼ To Install the HBA Software For the Linux OS 1. Go to the Emulex support site for Sun Microsystems at: http://www.emulex.com/sun/support/index.jsp 2. Locate the Sun StorageTek section, and click the model number (SG-XPCIE1FC- EM8-Z) for the HBA you want to install.
  • Page 53: Installing Software For The Windows Server 2003 Or Windows Server 2008 Os

    ▼ To Install the HBA Software For the VMware Technology You must obtain the drivers from VMware. 1. Go to the Emulex support site for Sun Microsystems at: http://www.emulex.com/sun/support/index.jsp 2. Locate the VMware section, and click the model number (SG-XPCIE1FC-EM8- Z) for the HBA you want to install.
  • Page 54: Configuration And Diagnostic Utilities

    ▼ To Install the Software For the Windows Server 2003 or Windows Server 2008 OS 1. Go to the Emulex support site for Sun Microsystems at: http://www.emulex.com/sun/support/index.jsp 2. Locate the driver section for Windows. 3. Download the Driver Kit by clicking Download.
  • Page 55: Reboot Fails On The Sparc Enterprise M8000 System (6728135)

    C H A P T E R Known Issues This chapter contains any known issues with the HBA. Reboot Fails on the SPARC Enterprise M8000 System (6728135) On the SPARC Enterprise M8000 system, if you use the stmsboot command to provide dual paths to the boot device, on occasion the boot device is not found and the reboot does not succeed.
  • Page 56 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide • December 2008...