HG4930 Installation and Interface Manual

Normal Operation Mode Description

The serial data interface is operational within 300 milliseconds after the last applied power form is
within the specified tolerances and the reset line is inactive.
The IMU transmits a fixed pattern 0x5555 (Hex) in place of Control sensor data and 0x55555555
(Hex) in place of Inertial sensor data until the completion of Power Up BIT.
The IMU completes Power Up BIT and report the results within 400 milliseconds after power is
within specified tolerances and IMU Reset is inactive.
Figure 3. Power Up Sequence
Supervisor Reset or
Power
External (IMU) Reset
Applied
Released
<= 40ms
Serial Data
|
aerospace.honeywell.com/HG4930
No Data
< 260 ms
<= 260 ms
<= 400 ms
<= 440 ms
Time
Normal
Fixed Data Pattern
Serial Data