Summary of Contents for Sun Microsystems SUN NETRA CP3000
Page 1
Sun Netra CP3000 Advanced ™ Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide for the AMC.1-HDD SAS Disk Sun Microsystems, Inc. www.sun.com Part No. 820-7175-11 March 2010, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
Page 2
Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Solaris, Netra et le logo Netra sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc., ou ses filiales, aux Etats-Unis et dans d’autres pays.
Contents Preface vii Getting Started 1–1 System Requirements 1–2 1.1.1 Operating Systems Compatibility 1–2 1.1.2 Chassis Compatibility 1–2 1.1.3 Blade Server Compatibility 1–2 1.1.4 Electrical and Environmental 1–3 Unpacking 1–3 Handling AMCs 1–4 AMC Faceplate 1–5 AMC LEDs 1–6 Removing and Installing AMCs 1–8 1.6.1 Removing an AMC 1–8 1.6.2...
Page 4
IPMI Controller 3–2 FRU Information 3–4 Sensors 3–5 Firmware and Software Upgrades 3–6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Hard Drive Disk 2–3 Power Regulator 2–3 SAS Controller 2–4 Flash 2–4...
Page 5
Configuring the AMC 4–1 Configuration Tools 4–2 Boot BIOS Utility 4–2 4.2.1 Features and Configurations 4–3 4.2.2 Launching the Boot BIOS Utility 4–3 OpenBoot BIOS 4–5 Extensible Firmware Interface (EFI) BIOS 4–6 Enabling and Disabling Channel Ports 4–6 A. Connectors and Ports A–1 Connector Locations and Assignments A–2 Connector Pinouts A–2 SAS Controller Ports A–4...
Page 6
C.4.2 Regulatory Information C–5 C.5.1 C.5.2 Index Index–1 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 EN 55022 Emissions C–4 EN 55024 Immunity C–4 FCC (USA) C–5 Industry Canada (Canada) C–5...
Preface The Netra™ CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide describes the installation and configuration of the Sun Netra CP3000 AMC.1-HDD SAS disk. This guide also includes information about software, environment specifications, connectors, and certifications.
You can submit your comments by going to: http://www.sun.com/hwdocs/feedback Please include the title and part number of your document with your feedback: Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide, part number 820-7175-11. Preface...
Page 10
Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Getting Started This chapter provides information and procedures needed to install and make the Sun Netra CP3000 AMC.1-HDD SAS disk operational. This chapter should be read before unpacking and installing the AMC. In addition to this chapter, refer to the following safety document: Important Safety Information for Sun Hardware Systems (816-7190) Caution –...
Sun blade servers: Sun Netra CP3060 blade server ■ Sun Netra CP3220 blade server ■ Sun Netra CP3250 blade server ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
1.1.4 Electrical and Environmental Appendix B Caution – None of the integrated chips junction temperature should exceed 125˚C. The AMC requires air flow to meet this requirement. Testing should be done in the shelf to find the quantity of air flow needed. The recommended minimum air flow is 50 LFM.
AMC connectors and components have very thin pins that bend easily. Be careful of small parts located on the component side of an AMC. ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Transport an AMC in an antistatic bag. ■ AMC Faceplate The following shows the faceplate of the Sun Netra CP3000 AMC.1-HDD SAS disk. AMC.1-HDD SAS Disk Faceplate FIGURE 1-1 Note – The AMC is available in different capacities (in gigabytes). The illustration shows a generic faceplate.
Blue Green describes in detail the different hot-swap BLUE LED states. TABLE 1-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 State Description Management power is available to the AMC, and the AMC can safely be extracted.
Page 17
Hot-Swap BLUE LED States TABLE 1-2 Order Visible State Solid Blinking (from solid) Blinking (from off) Note – An AMC should be hot-swapped only when the LED is solid blue. State Description M1 FRU Inactive The Intelligent Platform Management Interface (IPMI) microcontroller is booted, but the payload is not.
3. If the blade server must be removed to access the AMC, go to “Removing a Blade Server and AMC” on page Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1-12.
Page 19
Note – Depending on how the Shelf controls deactivation, the Shelf might not initiate deactivation when you disengage the ejector latch. If so, either configure the Shelf to allow deactivation via latch opening or deactivate by other methods. 4. For the AMC, initiate the hot-swap deactivation sequence by pulling the injector/ejector latch out half way ( The Hot-Swap LED starts blinking.
Page 20
Out (OUT) When OUT, the latching mechanism is released and the module can be extracted. Wait for the Hot-Swap LED to stop blinking before pulling the latch all the way out. 1-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Page 21
7. Remove the AMC. Removing the AMC FIGURE 1-3 8. Replace the AMC with another AMC ( ) or install a filler panel. FIGURE 1-7 Note – Be sure to follow handling instructions. See Section 1.3, “Handling AMCs” on page 1-4.
2. Disengage the injector/ejector mechanisms at the top and bottom of the blade server to notify software that the board is about to be removed. Wait for the Hot-Swap LED to light. 1-12 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 FIGURE 1-4...
Note – Depending on how the Shelf controls deactivation, the Shelf might not initiate deactivation when you disengage the ejector latch. If so, either configure the Shelf to allow deactivation via latch opening or deactivate by other methods. 3. Disconnect all cables connected to the switch. 4.
Page 24
5. Prepare the AMC by fully opening its injector/ejector latches to the OUT position. 1-14 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Section 1.3, “Handling AMCs” on page Section 1.2,...
Page 25
Opening the Injector/Ejector Latch FIGURE 1-6 Figure Legend Fully In (IN) When IN, the module communicates to the shelf manager that the module is not in the hot-swap state, and the shelf manager communicates with the MMC. This position is for normal operation.
Page 26
7. Keeping the AMC aligned in the guides, slide it in by pressing on the AMC faceplate until the AMC faceplate is flush with the blade server faceplate. 1-16 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Page 27
Inserting the AMC Into a Blade Server FIGURE 1-7 8. Push the ejector latch in fully. If system power is on and AMC is installed properly, the AMC board Hot-Swap LED lights up. The Hot-Swap LED blinks for several seconds, then goes off. If the Hot-Swap LED does not go off after several seconds, push firmly on the injector/ejector handles to ensure that they are pushed in all the way.
1. If there are other LSI controller chips present in the system, then the user has to determine the proper controller number. 1-18 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Note – This utility has many other uses and adjustable values. Parameter adjustments are permanently committed to flash memory, and affect future behavior of the AMC. Only advanced users who fully understand the technical implications should modify parameters. A full description of parameters and functions is in LSIUtil Configuration Utility User’s Guide, published by LSI.
Page 30
1-20 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
C H A P T E R Overview This chapter introduces the key features of the AMC. This chapter includes a product definition, a list of product features, and functional block diagrams with brief descriptions. This chapter can be used to compare the features of the AMC against the needs of a specific application.
■ Support for SSP, STP, and SMP, as defined in the Serial Attached SCSI (SAS) ■ Specification, version 1.0 Drive over-current protection ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Support for SATA, as defined in the Serial ATA Specification, version 1.0a. ■ Key Components The following figure and sections describe key components of the Sun Netra CP3000 AMC.1-HDD SAS disk. Top-Level AMC Layout FIGURE 2-1 2.2.1 Hard Drive Disk The Sun Netra CP3000 AMC.1-HDD SAS disk provides a single SAS hard drive,...
AdvancedTCA shelf managers. This MMC controls and monitors the following: Hot-swap communication with the shelf manager ■ Inlet air temperature ■ Voltage monitoring ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Chapter...
e-Keying as described in the AMC.0 specification ■ FRU information ■ LED indicators for hot-swap and OOS (out of service) ■ 2.2.6 Port Connectors The AMC includes connectors to communicate with the host board and take its interfaces outside the ATCA chassis. Refer to descriptions and pin-outs.
Page 36
Hot Swap Blue Long blink Short blink Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Description and Function Out of Service: fault set by shelf manager, or 12V payload power not detected.
If you have any technical questions or support issues that are not addressed in the Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller documentation set or on the web site, contact your local Sun Services representative.
The Media Access Control (MAC) address label contains the MAC address for the blade server in printed and barcode form. Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 FIGURE 2-4 ). The Sun barcode...
Page 39
Sun Netra CP3000 AMC.1-HDD SAS disk Barcode Labeling FIGURE 2-4 Figure Legend Final Assembly Number: • Assembly process label, where xxx denotes disk drive capacity • Rzz = Assembly Revision (Refer to Bill Of Material) where zz is a numeric revision Sub-Assembly Number: •...
For disposal or recycling information, please contact your local authorities or the Electronic Industries Alliance at http://www.eiae.org/. 2-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Managing the AMC This chapter describes the AMC management software. The Sun Netra CP3000 AMC.1-HDD SAS disk includes an IPMI-based Module Management Controller (MMC) that meets all requirements set out in the PICMG AMC.0 specification. The MMC allows detection of the module by the carrier board and manages communication between the AMC.1-HDD SAS disk and management...
Broadcast Get Device ID Messaging Commands Send Message Event Commands Platform Event Sensor Device Commands Get Device SDR Info Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 IPMI/PICMG/AMC Specification NetFn 17.1 17.9 18.7 23.3...
Page 43
Supported IPMI Commands (Continued) TABLE 3-1 Get Device SDR Reserve Device SDR Repository Get Sensor Reading Factors Set Sensor Hysteresis Get Sensor Hysteresis Set Sensor Threshold Get Sensor Threshold Set Sensor Event Enable Get Sensor Event Enable Rearm Sensor Events Get Sensor Event Status Get Sensor Reading FRU Device Commands...
YY = year (4 = 2004, 0 = 2010) NT = multiuse code WW = work week SSSS = sequence number (0-9999) Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 AMC.1-HDD SAS Disk 0 (EN-English) See note 1 Sun Microsystems, Inc.
Sensors The AMC.1-HDD SAS disk module management is connected to sensors monitoring key board voltages and temperatures. Data records from the following sensors are accessible using IPMI commands: Hot-swap ■ +12V payload power ■ +3.3V management power ■ Board and inlet temperature ■...
Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller ■ Product Notes (820-7174) README files within the download package ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
C H A P T E R Configuring the AMC This chapter describes how to configure the AMC using the SAS Boot BIOS Configuration Utility, the OpenBoot™ BIOS, and the Extensible Firmware Interface (EFI) Boot Services Driver. This chapter contains the following topics: Section 4.1, “Configuration Tools”...
A, and attempts to boot from the first device it finds with a boot record. Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
4.2.1 Features and Configurations The Boot BIOS supports the following: Using multiple AMC.1 SAS modules ■ Applying global properties stored in flash ■ Selecting and configure up to 256 adapters ■ Automatic INT13 drive mapping for SAS drives ■ SAS topology discovery, including expander traversal ■...
Page 50
The Adaptor Properties menu is displayed, where you can view and modify AMC parameters. This menu provides the top-level view of AMC status and configurable parameters. Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Adapter Properties Menu FIGURE 4-2 5. Using the arrow keys, select the item of interest. 6. Press ENTER to display the next screen. OpenBoot BIOS For information about the OpenBoot BIOS, refer to the Sun Solaris OS and SPARC documentation. The documentation is available at the following site: http://www.sun.com/documentation/ Chapter 4 Configuring the AMC...
“disable” setting. You can enable these ports using lsiutil, a command line utility. For instructions, see Disabling SAS Ports” on page Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Section 1.7, “Enabling and 1-18.
A P P E N D I X Connectors and Ports This appendix describes the connectors and ports you can use to communicate with the host board and application-specific devices. A brief description of each connector and port is given, and a detailed description and pinout given for each connector. This appendix contains the following topics: Section A.1, “Connector Locations and Assignments”...
Pin# 'PRSNT1_L' 'AMC_VCC3' No Connect No Connect Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Function AMC.3 Serial Storage Port 2 AMC.3 Serial Storage Port 3 AMC.1 PCI Express lane 0 AMC.1 PCI Express lane 1...
Page 55
Pin Assignments (Continued) TABLE A-1 No Connect No Connect No Connect No Connect 'PORT1_PTX0_P' 'PORT1_PTX0_N' 'PORT1_PRX0_P' 'PORT1_PRX0_N' 'TX_SAS_2+' 'TX_SAS_2-' 'RX_SAS_2+' 'RX_SAS_2-' 'TX_SAS_3+' 'TX_SAS_3-' 'RX_SAS_3+' 'RX_SAS_3-' 'PCIe_RX1_N' 'IPMI_SCL_L' 'PCIe_TX2_P' 'PCIe_TX2_N' 'PCIe_RX2_P' 'PCIe_RX2_N' 'PCIe_TX3_P' 'PCIe_TX3_N' 'PCIe_RX3_P' 'PCIe_RX3_N' 'IPMI_SDA_L' No Connect No Connect No Connect No Connect PREFCLKP...
These SAS ports are shipped with PHY’s disabled and are not driving AMC ports 2 and 3. This default configura- tion avoids incompatibilities with systems that have other initiators driving these AMC ports. Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 No Connect...
e-Keying Ports The AMC.1-HDD SAS disk connects up to two SAS ports on the AMC connector. These ports are defined by the AMC.3 specification for serial storage. The module designates four PCI Express ports, per AMC.1 specification. The link type and link type extension are defined in the following table.
Page 58
Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
A P P E N D I X Environment Specifications This appendix describes the electrical, environmental, and mechanical specifications. It includes illustrations of the board dimensions. This appendix contains the following topics: Section B.1, “Electrical and Environmental” on page B-2 ■...
The environmental values are listed in the following table. Environmental Specifications TABLE B-2 Specification Temperature Relative humidity Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 SAS (Max Less than 100 mA 1.5A (18W) 1.0A (12W) 0.75A (9W) Less than 0.4W...
Page 61
Environmental Specifications (Continued) TABLE B-2 Vibration Operating Nonoperating Shock Operating Nonoperating Altitude Operating Nonoperating Performance Seek time avg Seek time max Interface MTBF MTBF Values by Temperature TABLE B-3 Temperature MTBF 0ºC 1234247.92 5ºC 1104059.81 10ºC 977994.82 15ºC 858417.32 20ºC 747143.26 25ºC 645377.07...
MTBF: 630,000 hours ■ One year limited warranty ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 for normal operating 0 VDC to +13.2 VDC 3.135 VDC to +3.465 –40 to +70˚ Celsius 5% to 95% at 29˚...
Mechanical This section includes the mechanical specifications for dimensions and weight. The AMC.1-HDD SAS disk meets the PICMG 3.0 AdvancedTCA Specification R2.0 ECN002 and AMC.0 R2.0 for all mechanical parameters. B.3.1 Board Dimensions and Weight The AMC.1-HDD SAS disk is 181.5 mm by 73.5mm and conforms to the component height requirements of a mid-size module and can be configured as a full-size module.
Page 64
Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
A P P E N D I X Agency Certifications This appendix lists standards agencies and the certifications related to the Sun Netra CP3000 AMC.1-HDD SAS disk. This product was tested in an EMC-compliant chassis and meets the requirements for EN55022 Class A equipment. Compliance was achieved under the following conditions: Conductive chassis rails connected to earth ground, providing the path for ■...
Interface At The Input To Telecommunications Equipment; Part 2: Operated by direct current (DC ETSI EN 300 753, October 1997, Acoustic Noise Emitted By Telecommunications ■ Equipment Certification is dependent on your configuration. Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Safety UL/cUL 60950--1 Safety for Information Technology Equipment (UL File ■ #E138926) EN/IEC 60950-1:2001, 1 ■ Technology Equipment (TUV CB certificate and report) The following group and/or national deviations were considered: CENELEC Common Modifications, Annex ZA ■ AU (Australia and New Zealand) ■...
IEC 61000-4-6:1996 EMC - Part 4: Testing and measurement techniques - Section 6: ■ +A1:2001 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Immunity to conducted disturbances induced by radio frequency fields...
Regulatory Information Caution – If you make any modification to the AMC not expressly approved by Sun, you could void your warranty and/or regulatory authority to operate the component. C.5.1 FCC (USA) This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules.
Page 70
1. Ce dispositif peut ne pas causer l'interférence nocive. 2. Ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée. Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010...
Page 71
Index Numerics 10GbE local PHY, 3-2 absolute maximum ratings, B-4 AMC flexing, preventing, 1-4 antistatic bag, 1-3 board status, 1-6 board voltages, monitoring, 2-4 cable management bracket lowering, 1-12 cable management bracket, lowering, 1-12 certification, C-2 comments, about this book, ix connector locations, A-2 deactivating the AMC, 1-10 dimensions and weight, B-5...
Page 72
3-6 static electricity, 1-1 storage temperature, B-4 Sun Services, 2-7 Index-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March support, 2-7 switches, LEDs, 1-6 system requirements, 1-2 Telcordia Industrial Reliability program, B-4...
Need help?
Do you have a question about the SUN NETRA CP3000 and is the answer not in the manual?
Questions and answers