Mounting and Connection Instructions Viewguard DUAL / AM BUS-2/BUS-1

13. Connection diagram

13.1
Connection BUS-2 or BUS-1
With
Version 1
(fig. 9) in the case of a removed detector the voltage supply is interrupted for the rest of the BUS users. If this is not requested then
Version 2
(fig. 10) is applicable.
Version 1
BUS-2
BUS-1
Detector 1
Fig. 9
13.2
Detector group connection
This connection enables the integration of contacts in the BUS
system. (Not possible in SCM 3000 mode, see 3.2)
Operation on BUS-2:
If the detector zone is not used, it should be programmed to detector
zone "zero"!
Operation on BUS-1:
The detector zone is connected in an "OR" function with the detector
alarm. If the detector zone is not used, it must be terminated with
12k1.
BUS-2
BUS-2
BUS-1
BUS-1
Detector
Fig. 11
15. Accessories
033390
Adjustable joint
Swivel range: Horizontal
as per VdS and EN grade 2
033588
Ball-and-socket set for wall and corner mounting
Swivel range: Horizontal
not as per VdS and EN
033391
Seal
(packaging unit = 20)
Detector n (max. 63)
(ZONE)
Contact(s)
potential-free detectors
without memory function
12k1
±20°,
Vertical +4° up to -8°
±45°,
Vertical
±20°
Version 2
BUS-2
BUS-1
Detector 1
Fig. 10

14. Technical data

Operating voltage U_b
Operating voltge range
Current consumption at U_b=12 V DC:
PIR
Microwave
LED
Range (programmable)
PIR and MW together
PIR sensor
PIR sensitivity (programmable)
Anti-Mask function (only AM detector)
Frequency microwave
Installation position
Protection class as per DIN 40 050
Environmental class as per VdS
Operating temperature range
Storage temperature range
Dimensions W x H x D
Colour
VSÖ approval
033442.20
033443.20
The detectors Viewguard DUAL AM BUS-2/BUS-1, Item
no. 033442.20 and Viewguard DUAL BUS-2/BUS-1, Item
no. 033443.20 when used as intended, comply with the
basic requirements of Article 3 of the R&TTE Guideli-
ne1999/5/EU.
The EU conformity declaration can be downloaded at
"www.honeywell.com/security/de"
under Service-/ Download
The devices may only be sold and operated in the following countries:
Germany, Austria, Switzerland, Liechtenstein, Poland, Slovakia, Czech
Republic, Luxembourg, Turkey, Greece, Lithuania, Hungary, Belgium,
Netherlands, Bulgaria and Romania.
11
Detector n (max. 63)
12 V DC
8.0 V to 15 V DC
0.6 mA (BUS-2)
3.0 mA (BUS-1)
6 mA
4 mA
8 / 11 / 13 / 15 m
temperature compensated
normal / high
up to 30 cm
9.35 GHz (X band)
vertical, optics at bottom
IP 30
II
-10 °C to +55 °C
-25 °C to +70 °C
64 x 158 x 48 mm
White
(similar to RAL 9010)
VSÖ.E:W081006/28E
VSÖ.E:GS-N081006/29E