IBM PCIe3 x8 SAS RAID internal adapter 6 Gb Manual page 101

Table of Contents

Advertisement

a. In the navigation area, click the Serviceability icon
Events Manager.
b. Examine the service action event log for any open service action events.
3. Are any service action events open?
v Yes: Continue with the next step.
v No: If the system attention LED is still on, turn off the LED as described in "Activating and
deactivating LEDs" on page 91. Return the system to the customer. This completes the repair.
4. Record the list of open service action events.
5. From the list of serviceable events recorded in step 4, complete the following steps 6 - step 32 on
page 84 for each open service action event.
6. Determine the error class of the serviceable event. Record for future use.
7. Examine the details of the open service action event.
Is the error code that is associated with this service action event the same as recorded in step 1 on
page 82?
v Yes: Go to step 11.
v No: Continue with the next step.
8. Examine the FRU list of the service action event. Are any FRUs listed for the service action event?
v Yes: Continue with the next step.
v No: Go to step 11.
9. Is the FRU list identical that is, the same FRUs, same number of FRUs, and same order of FRUs) to
the FRU list of the error code recorded in step 1 on page 82?
v Yes: Go to step 11.
v No: Continue with the next step.
10. The FRU list is different. Is the FRU you replaced and recorded in step 1 on page 82 in the list of
FRUs for this service action event?
v Yes: Continue with the next step.
v No: Go to step 32 on page 84.
Note: Some service action events will remain open when you leave this MAP. Further service
actions might be required to complete the repair.
11. Examine the details of this service action event, and record the partitions involved in this service
action event for use in a later step.
12. Is the error code associated with this service action event of the form A11-xxx or A01-xxx?
v Yes: Continue with the next step.
v No: Go to step 17 on page 84.
13. Have you begun a list of Axx partitions from prior service action events that you processed in this
MAP?
v Yes: Go to step 15.
v No: Continue with the next step.
14. Begin a new list of Axx partitions by copying the list of partitions obtained in step 11. Go to step 16.
15. Add the partition list obtained in step 11 to the existing list of Axx partitions obtained from
processing previous service action events in this maintenance analysis procedure (MAP).
16. Remove all entries in the list of all partitions you recorded in step 11. If you are referred to the list of
partitions obtained in step 11 in future steps, the list is empty. Go to step 17 on page 84.
Common procedures for removing or replacing the PCIe3 x8 SAS RAID internal adapter 6 Gb
, and then click Serviceable
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

5148-21l5148-22l8284-22a8247-21l8284-21a8247-22l

Table of Contents