Optex OVS-01CC Installation Instructions Manual page 16

Vehicle detection sensor for vehicle counting
Hide thumbs Also See for OVS-01CC:
Table of Contents

Advertisement

[3] Stand at the edge of the vehicle lane (see Figure [B]), walk along the border and verify that the operation
indicator keeps blinking green (not detecting).
If the operation indicator changes to blinking red (detecting), adjust the sensor angle and/or range setting
again. After the adjustment,perform calibration again and start from step [2].
[4] After verifying the detection area, press the Area Check button again.
It switches the mode back to Normal Operation Mode and the operation indicator turns a solid green.
*If it keeps blinking green (no detection) for more than 30 seconds, it will automatically change back to the
Normal Operation Mode.
■ System Operation Check
After verifying the detection area, check the entire operation system using a vehicle.
For the operation check, verify the proper operation with a vehicle on the left side, center, and right side of the
lane.
Sensor
Sensor
[B]
Standby
Area Check
Detection
Calibration
Calibration Area Check
-16-
Operation indicator
stays blinking green.
Left side of the lane
Center of the lane
Right side of the lane

Advertisement