Adapter Firmware Installation Instructions - IBM 57D7 Manual

Adapter write cache
Table of Contents

Advertisement

Ensure the iprutils daemons are enabled to start on the next boot. Please note, that the iprinit daemon
must be enabled and running for this write cache feature to get enabled at boot time.
# chkconfig iprinit on
# chkconfig iprupdate on
# chkconfig iprdump on
3.2

Adapter Firmware Installation Instructions

The required 14511900 version of SAS adapter firmware to enable this feature can be downloaded from IBM
Fix Central at the following URL:
Power%2BIO%2BFirmware&product=ibm/io/featurecode/EJ0T&release=all&platform=all&function=all&source=
fc. The pci.1014034A.51-14511900-1.Linux.noarch.rpm file should be downloaded. Once downloaded,
install to your Linux system with the rpm command.
# rpm -ivh pci.1014034A.51-14511900-1.Linux.noarch.rpm
To begin the process of installing the new adapter firmware, first login as root on the target server, then
run iprconfig.
You should see a screen similar to this:
Select one of the following:
1. Display hardware status
2. Work with disk arrays
3. Work with disk unit recovery
4. Work with configuration options
5. Work with microcode updates
6. Devices Statistics
7. Analyze log
Selection:
e=Exit
Select option 5.
Work with microcode updates, and press Enter.
IBM Power Systems 57D7/57B4 Adapter Write Cache
http://www.ibm.com/support/fixcentral/main/quickorder?parent=
IBM Power RAID Configuration Utility
Version 1.3 dated May 19, 2016
8 of
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

57b4

Table of Contents