AEG Thyro-A H1 Series Operating Instructions Manual page 38

Ethernet bus module profinet
Table of Contents

Advertisement

2. Acyclic parameter table Thyro-C07
Table B: Thyro-C07 controller parameters slot 1-8
Controller parameter
Symbol
Name
1
I_TYP
Controller type current
2
U_TYP
Controller supply voltage
3
P_TYP
Controller type output power
6
BETR
Operating mode
7
AN1
Phase angle of 1st half wave
8
SST
9
SDN
Soft stop duration (given)
10
T0
Cycle period duration
11
MP
Minimum interval
12
TSMAX
Maximum cycle turn on time
13
TSMIN
Minimum cycle turn on time
14
V_IE
Front pulse stop
15
H_IE
Back pulse stop
16
RE
Control (analog output value)
17
TI_1
PI controller, I part
18
KP_1
PI controller, P part
19
KR_1
PI controller, counter P part
20
Temperature coefficient of the heating tape
21
UEMA
Effective voltage setpoint maximum
22
IEMA
Effective current setpoint maximum
23
PMA
Power setpoint maximum
24
SW_ENABLE
Setpoint activation
27
SW_REGLER
Setpoint x2.4
28
OF_1
Actual value output offset 1
29
FA_1
Scale end value actual value output 1
30
SPG_MIN
Mains voltage monitoring min.
31
SPG_MAX
Mains voltage monitoring max.
32
UN_S
Undercurrent monitoring
33
RELAIS_CTRL_2
Relay configuration 2
34
LASTBRUCH_MIN_
Load fault, minimum value
ABS
36
SYNC_ADR
Synchro cycle address
37
IMAB
Pulse switch-off in case of failure
38
STA_RE
Control start controller analog setpoint
39
STE_RE
Control end controller analog setpoint
41
MOSI_FA
Peak current value limit
42
DAC_1_CTRL
Analog output configuration 1
44
VERS_T
Version day
45
VERS_M
Version month
46
VERS_J
Version year
48
Controller inhibit
49
RELAIS_CTRL
Relay configuration 1
50
Save
56
MITTEL
Averaging analog output 1
84
TEMP
Temperature
109
MITTEL_2
Averaging analog output 2
110
OF_2
Actual value output offset 2
111
FA_2
Scale end value actual value output 2
112
DAC_2_CTRL
Analog output configuration 2
115
MITTEL_3
Averaging analog output 3
116
OF_3
Actual value output offset 3
117
FA_3
Scale end value actual value output 3
118
DAC_3_CTRL
Analog output configuration 3
119
U_MIN
Voltage limit minimum
120
U_MAX
Voltage limit maximum
121
I_MIN
Current limit minimum
122
I_MAX
Current limit maximum
123
P_MIN
Power limit minimum
124
P_MAX
Power limit maximum
Data
Value
Combo-opt.
type
range
u16
0...
u16
0...1000
u32
0...
u16
0...3
reserved, TAKT, VAR, QTM
u16
0...180
u16
0...1000
u16
0...1000
u16
0...1000
u16
0...10
u16
1...T0
u16
0...T0
u16
0...180
u16
0...180
u16
0...9
Uload2, Uload eff, Iload2, Iload eff, reserved, real power,
reserved, reserved, without regulation, temperature
u16
0= aus
0...65535
u16
0= aus
0...65535
u16
0...65535
u16
0...65535
u16
0...
u16
0...
u32
0...
u16
0...3
bit0=1 setpoint x2.4 active, bit1=1 setpoint master active
u16
0...4096
u16
0...4096
u16
0...4096
u16
0...1000
u16
0...1000
u16
0...1
off, on
u16
0...65535
bit coded
u16
0...4505
u16
0...65535
u16
0...65535
bit coded
u16
0...65535
u16
0...65535
u16
0...4096
u16
0...11
u16
1...31
u16
1...12
u16
0...9999
u16
0...1
off, on
u16
0...65535
bit coded
u16
0...1
off, save
u16
0...65535
u16
-50...150
u16
0...65535
u16
0...4096
u16
0...4096
u16
0...11
u16
0...65535
u16
0...4096
u16
0...4096
u16
0...11
u16
0...65535
u16
0...65535
u16
0...65535
u16
0...65535
u32
0...
u32
0...
38