Parameter Sets For Fdoot, Fdo And Fdt Detectors; Table 31: Supported Sinteso ™ Elements - Siemens SIGMASYS C Manual

Multifunctional danger control and indicating panels
Table of Contents

Advertisement

Combination detector
Flame detector
Linear smoke detector
Manual detector
Alarm sounder
Signal base
Input module
Input/output module
FDnet transponder
Line disconnector
Table 31: Supported Sinteso
Nothing needs to be mechanically adjusted on the detectors themselves. The detectors are
supplied ex works with the appropriate sets of parameters. The PLAN D100 configuration tool
can be used to adjust the detectors optimally to the conditions of the installation site. By se-
lecting the right parameters you can set the detector to specific potential fire events and likely
environmental influences.
For the FDOOT241-9 neural fire detector you can also select the parameter sets of the
FDO241 wide spectrum smoke detector and the FDT241 heat detector. In this case the
FDOOT241-9 neural fire detector will behave like the FDO241 wide spectrum smoke detector
or FDT241 heat detector.
For S-LINE detectors the switching of the parameter sets can be controlled on a
time/process-related basis.
Two parameter sets within DOOT or DO or DT can be switched using an operating input on
the control and indicating panel, an operation on the operating panel of the control unit, or us-
ing the time controls on the control and indicating panel. Both parameter sets are fixed in both
PLAN D100 and in SIGMASYS detectors.
Two customized detector parameter sets can be selected for S-LINE detectors with PLAN
D100 and downloaded to the detectors via the line tester.
Installation conditions for Sinteso™ detectors and their associated parameters can be found
in the detectors' technical description.
12.6.3

Parameter sets for FDOOT, FDO and FDT detectors

Parameter sets
DOOT: high
DOOT: robust
DOOT: balanced
DOOT: suppression
DOOT: fast response
DOOT: high compensation
Multifunctional Danger Control and Indicating Panels SIGMASYS C and M (M-Modules)
Best.Nr. A24205-A337-B970 – Edition 12 (03/07)
FDOOT221
FDOOT241
FDF241-9
FDF221-9
FDL241-9
FDM223
FDS221
FDSB291
FDCI222
FDCIO222
FDCIO223
FDCL221
elements
FDOOT241
FDOOT221
X
X
X
Standard
X
X Standard plus
X
X
X
Used as combination detector
2 selectable parameter sets
Used as combination, smoke or heat detector
5 selectable parameter sets
For indoors and outdoors with
3 infrared sensors and sun resistance
1 infrared sensor for use without interference
sources
6 parameter sets
Push-button detector, actuated by pressing the
button.
11 tones and 3 volume levels, shrill alarm sound
11 configurable tones and 2 volume levels
4 contact inputs, monitored for wire breakage and
short circuit
4 contact inputs, monitored for wire breakage and
short circuit
4 x 30VDC 4A relay outputs
2 VdS alarm or monitored control lines
For connecting several spur lines lying next to one
another to one ring line
FDO241
FDO221
12 Monitored lines
FDT241
FDT221
87 / 128

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigmasys m

Table of Contents