GE Baker Hughes Masonelian BR200 Instruction Manual

GE Baker Hughes Masonelian BR200 Instruction Manual

High capacity volume booster relays

Advertisement

Quick Links

Masoneilan*
BR200/BR400
High Capacity Volume Booster Relays
Instruction Manual (Rev. B)
BHGE Data Classification : Public

Advertisement

Table of Contents
loading

Summary of Contents for GE Baker Hughes Masonelian BR200

  • Page 1 Masoneilan* BR200/BR400 High Capacity Volume Booster Relays Instruction Manual (Rev. B) BHGE Data Classification : Public...
  • Page 2 BHGE © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 3 REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, BHGE (BAKER HUGHES, A GE COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED.
  • Page 4: Product Description

    A bypass valve allows a controlled flow of input signal direct to the output to obtain stable control for small or slow changing input signals. Figure 1 - Cut-away View of BR400 Booster Relay BHGE © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 5: Pneumatic Supply

    The preferred orientation is with the exhaust openings pointing down; however horizontal mounting is acceptable. Masoneilan BR200/BR400 High Capacity Volume Booster Relays | 5 © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 6: Specifications

    1/4" NPT or Rc Approximate Weight 0.7 kg (1.5 lbs) for BR200 and 1.4 kg (3 lbs) for BR400 Table 1 - Specifications Flow Characteristics Figure 2 - Flow Characteristics BHGE © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 7: Operation

    Adjustment of bypass valve during plant operation: Adjusting bypass value when control valve is in service may generate sudden valve opening change or oscillation. Masoneilan BR200/BR400 High Capacity Volume Booster Relays | 7 © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 8: Maintenance

    Check also that supply and exhaust valve seats are clean. If output pressure is not stable or is slow to respond, check setting of bypass needle valve. See bypass valve setting procedure under "Operation". BHGE © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 9 Note: model BR400 is available in stainless steel for marine offshore applications. Model BR400 ø127mm (5") 90mm (3.5") 119mm (4.7") 87mm (3.4") Figure 6 - BR400 Construction and Dimensions Masoneilan BR200/BR400 High Capacity Volume Booster Relays | 9 © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 10 Notes 10 | BHGE © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 11 Notes Masoneilan BR200/BR400 High Capacity Volume Booster Relays | 11 © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 12 The BHGE logo is a trademark of Baker Hughes, a GE company LLC. GE and the GE monogram are trademarks of the General Electric Company used under trademark license.

This manual is also suitable for:

Baker hughes masonelian br400

Table of Contents