Summary of Contents for Digital Equipment DECstation 5000 Model 150
Page 1
DECstation 5000 Model 150 R4000 Series CPU Upgrade MLO-010159 Part Number: EK-4MMIN-UP.A01...
Page 2
Check the Shipment Contents If you are missing any of the components shown below, contact your Digital sales rep- resentative. Make sure the switch packet on the CPU is set as shown here. (Switch 1 in the off position, and Switch 2 in the on position.) CPU upgrade module Antistatic...
Page 3
Check the System Software IMPORTANT Versions of ULTRIX and UWS earlier than 4.3A do not support the R4000 series CPU upgrade. Enter this command to see which version of software is on your system: >> more /etc/motd If you do not have ULTRIX and UWS Version 4.3A or later, you must upgrade your software before you continue.
Page 4
Shut Down the System Software Follow these instructions to shut down your system software (ULTRIX and UWS Ver- sion 4.3A or later): 1. Enter this command at the superuser prompt (#) to shut down the software: # /etc/shutdown -h now 2.
Page 5
Remove the System Unit Cover 1. Turn off your system unit and any expan- sion boxes. Keep the system plugged in (grounded) to the wall outlet. 2. Unscrew the captive screw on the back of your system unit cover. 3. Slide the cover a few inches towards the front.
Page 6
Attach Your Wrist Strap Attach the antistatic strap to your wrist and to the side of the system box to ground it. MLO-010161 Caution: Do not touch anything inside the system unit until you have the antistatic wrist attached. Failure to use the antistatic wrist strap can result in damage to equipment.
Page 7
Remove the R3000 CPU Module 1. Push the PC board removal tool down over each of the mounting posts to un- lock them. 2. Pry the module up with your fingers. CPU module connector Heat sinks module Mounting posts PC board removal tool Mounting...
Page 8
Install the R4000 Series CPU 1. Align the board mounting holes over the mounting posts. 2. Push down on the board with your fingers until each mounting post locks and the CPU module connector is seated in the base module connector. Caution: Do not push on the heat sink.
Medallion tabs System cover (upside down) MLO-010012 3. Choose the correct system medallion: Workstation: DECstation 5000 Model 150 Server: DECsystem 5000 Model 150 4. Snap in the new medallion and turn the cover right side up.
Replace the System Unit Cover Replace the system unit cover and tighten the captive screw. Captive Screw MLO-010232...
Page 11
Attach Conversion Label Place the product conversion label on the top of your system unit cover. Product conversion label MLO-010164 Turn Your System On 1. Turn on your system unit and all expansion boxes. The system will run startup tests. 2.