INTRODUCTION CONGRATULATIONS Dear customer, This handbook is designed for the customers, who bought a compressor for the choice of the professional compressor hobby use and contains the necessary proves your technical competence and your information for the determination of the love of beautiful designs.
Page 3
MODEL When contacting the manufacturer, please specify the information provided on the label attached to the compressor. 0 Producer 1 Pump 2 Noise 3 Voltage, power supply 4 Production year 5 Tank volume 6 Frequency 7 Name of the family 8 Maximum working power 9 Engine power 10 Model...
Page 4
SETTING IN MOTION - SWITCHING OFF POSITIONING The compressor is to be placed in a room which is easy to air, so that dust, sawdust, gasses or explosive substances do not enter the air outlet openings, and should moreover be far from heat releasing devices. CONNECTION TO THE ELECTRIC INSTALLATION Make sure that the voltage of the plug...
Page 5
SETTING IN MOTION - SWITCHING OFF After carrying out the above mentioned controls, connect the compressor to the electric installation and switch the button onto the “ON-1” position (fig. 5) . To switch off the compressor push the button to “OFF-0” position (fig.
OPERATION whereas the value shown on the WARNING manometer 6.2 refers to the inner tank The correct use of the electric pressure; compressor consists in alternating connect the pipe of the machine tool to running, that is for 60% of the total be used to the air outlet tap 7.3 and open time in operation.
MAINTENANCE DO NOT ACT AS FOLLOWS carried out every 200 hours. The suggested oils are AGIP SUPERDIESEL or AGIP WHILE THE COMPRESSOR GAMMA 40. IS IN OPERATION Place the compressor on inclined WARNING surfaces. Do not mix different oils. Cover the compressor or place it in areas, that cannot be aired.
Page 8
MAINTENANCE B - Air leakage Check whether there are leaks in the joints. The compressor does not start or cuts out immediately A - Make sure that the line voltage corresponds to that indicated on the label. If the line voltage is higher the compressor could be damaged, whereas in case of lower voltage the motor does not pick-up properly and cuts out immediately.
Page 9
MAINTENANCE After switching off the compressor, The compressor is noisy and gives out it does not start again rhythmical and metallic sounds unplug the compressor; Stop the engine immediately and contact rotate the fan to make sure that the specialised technicians. system is not blocked;...
Need help?
Do you have a question about the PAC 2000 PL and is the answer not in the manual?
Questions and answers