96% efficient power direct vent commercial gas water heater

Advertisement

F
90+
ORCE
96% Efficient
Power Direct Vent Commercial Gas Water Heater
SPECIFICATIONS
BTU
MODEL
INPUT
NUMBER
PER
HOUR
SHE50 100NE
100,000
Manifold Pressure: 4.0 inches w.c. (.99 kPa); All models–Maximum Supply Pressure: 14 inches w.c. (3.48 kPa) Minimum Supply Pressure Natural Gas: 3.5 inches w.c.
(.87 kPa). Minimum Pressure Propane: 8.0 inches w.c. (1.99 kPa). Minimum Pressure must be maintained under both load and no-load (static and dynamic)
conditions.
DIMENSIONS
SHE50 100NE
A
INCHES
66-3/4
Top inlet and outlet: 3/4˝ male NPT
Side inlet and outlet: 3/4˝ female NPT
Gas inlet: 1/2˝ NPT
(Natural or Propane) gas water heater(s) shall be State Force™ 90+ model # SHE50 100NE, with 96% thermal efficiency, a storage capacity of 50 gallons, an input rating of 100,000 BTU per hour, a recovery
rating of 116 gallons per hour at 100ºF rise and a maximum hydrostatic working pressure of 150 psi. Water heater(s) shall be of power direct vent design, using 2, 3 or 4˝ PVC, CPVC or ABS pipe for horizontal and/or
vertical vent runs. Water heater(s) shall have: 1: Seamless, glasslined steel tank construction and a spiral-shaped heat exchanger placed entirely inside the tank, which shall be glasslined on the flue gas side to
protect against acidic condensate. 2: Advanced electronic control with large LCD display and advanced diagnostics. Water heaters shall incorporae the iCOMM
fault alert. 3: A 3-year limited warranty against tank leaks. Water heater(s) shall meet the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition of
ASHRAE/IESNA 90.1.
For complete information on limited warranties, consult written warranty
or contact the State Customer Care Center at 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For more information on State Water Heaters, contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
800-365-0024 Toll-free USA
www.statewaterheaters.com
RECOVERY–GALLONS
TANK
AT DEGREE RISE
SIZE
GALLONS
40ºF
50
291
B
C
D
49-1/4
22
15-3/4
Revised June 2011
PER HOUR
100ºF
140ºF
116
83
E
F
3
8
SUGGESTED SPECIFICATION
SHIPPING
WEIGHT
LBS.
255
Optional Concentric Vent Kit
*INSTALL IN ACCORDANCE WITH LOCAL CODES.
system for remote monitoring, leak detection and
Part # 9003910105
SCGSS01108