State Water Heaters SDV100-199 Specification Sheet page 2

Commercial gas water heater

Advertisement

Sandblaster
®
Force
Automatic Circulating and Automatic storage water heaters.When used singly or in
manifolded multiples with additional heaters or storage tanks, they can provide an
independent hot water system.When installed with a mixing valve, they can provide both
140°F general use hot water and 180°F sanitizing hot water simultaneously.
SDV80 140, SDV100 199, SDV100 260 and SDV100 400 models meet or exceed Federal
Efficiency Requirements prescribed by the Energy Policy and Conservation Act of 1992
(EPACT) for commercial water heaters.They also meet or exceed ASHRAE 90.1b-1992.
SDV75 70 meets or exceeds Federal Energy Efficiency Standards effective January 1,
1990, according to the National Appliance Energy Conservation Act (NAECA) of 1987.
Model Number
SDV75 70NE
SDV75 70PE
SDV80 140NE
SDV100 199NE*
SDV100 199PE*
SDV100 260NE
SDV100 260NE ASME
SDV100 400NE
SDV100 400NE ASME
First-Hour Delivery and Recoveries are rounded to nearest gallon.
Model SDV75 70 has
Dimensions are rounded to nearest
When ordering propane, change "N" to "P" in model number (SDV80 140PE).
All models available in Canada. When ordering, add "CGA" to model number
(SDV75 70NE CGA).
C
HOT
OUTLET
E
COLD INLET
AIR
EXHAUST
INTAKE
I
B A
D
H
SDV75 70
SDV80 140, SDV100 199, SDV100 260 & SDV100 400
Gas water heater(s) shall be a State Industries, Inc. Sandblaster Force, Model Number,
____________________, with a
Btu/Hour
gas, and a recovery rate of
degree Fahrenheit temperature rise.
Unit(s) shall be direct-vent design, with an automatic blower-powered, two pipe air intake and
exhaust system communicating directly with the outside of the building;.The blower shall have
a safety device that will not allow the operation of the pilot and main burners unless the blower
is in operation. Unit(s) shall have a combustion air passage that is internal to the outer jacket
of the water heater other than the intake and exhaust connections at the top of the water heater.
The units shall be equipped with an Intermittent Electronic Ignition control requiring an external
120 Volt power supply with a rating of 12 amps or less. The control system shall shut off the
gas supply to the unit within 4 seconds if the gas supply or pilot flame are interrupted.The tank
shall be additionally protected against premature failure in the following ways:
500 Lindahl Parkway, Ashland City,TN 37015
WA TER HEATERS
EC/SDV1/0601
Commercial Gas Water Heater
gas water heaters are design certified by the CSA International as
BTU Input
First Hour
Per Hour
Delivery
Gal.
Cap.
Natural Propane 100° Rise 80° 100° 140°
75
70,000
117
75
65,000
112
80
140,000 140,000
200
100
199,000
276
100
190,000
266
100
260,000 260,000
338
100
260,000 260,000
338
95
390,000 390,000
461
95
390,000 390,000
461
3
-inch water connections; all others have 1
1
-inch.
4
2
1
-inch.
4
Sandblaster
®
Force
gallon storage capacity, an input rate of
gallons per hour at a
©2001 State Industries, Inc.
Recovery
Dimensions in Inches
A
B
C
D
81
64
46
69
5
61
5
26
16
5
8
8
8
74
59
42
69
5
61
5
26
16
5
8
8
8
180 144 103 76
1
71
7
28
8
3
4
8
4
258 206 147 74
7
70
1
30
1
8
3
8
2
4
4
7
1
1
3
245 196 140 74
70
30
8
8
2
4
4
335 268 191 79
1
77
1
30
1
8
3
2
2
4
4
335 268 191 79
1
77
1
30
1
8
3
2
2
4
4
493 395 282 82
1
80
1
30
1
8
3
4
4
4
4
493 395 282 82
1
80
1
30
1
8
3
4
4
4
4
*Rear plumbing.
**Gas connection on Propane models is
ASME construction not available.
• NSF construction available, add 5˝ to height and
add NSK to model number (SDV80 140NE NSK).
+
Vent diameter depends on length of run. 4˝ diameter
up to 40 equivalent feet each run.
Venting System Requirements
1 The water heater requires its own (separate) venting system.
2 Venting cannot be connected to existing vent piping or chimney.
3 Venting may terminate vertically or horizontally to the outdoors.
4 Vertical and horizontal vent runs must be secured at 3
5 Vent piping cannot under any circumstances be run downhill.
6 Horizontal runs require a minimum
7 Vent pipes must be installed so that they can be visually inspected.
Maximum Equivalent Feet of Pipe With One 90° Elbow
SDV Series
Models
3" Schedule 40 PVC
SDV75-70
50'
SDV80-140
135'
SDV100-199
135'
SDV100-260
N/A
SDV100-400*
N/A
*The first 10 feet of exhaust vent run connected to this model must be run in CPVC or equivalent. The intake air
may be all PVC.
NOTE: Each 90° elbow is equivalent to 5 feet of pipe. Two 45° elbows are equivalent to 5 feet of pipe.
Sample Specifications
1.A
-year limited warranty against failure due to corrosion, metal fatigue or overheating
caused by the buildup of scale, film or other sediment.
2. Against electrolytic corrosion by multiple, factory-installed magnesium anodes.
3. Against failure due to overheating caused by the buildup of scale, film and other sediment
by a construction which incorporates an annular ring, which fits inside the tank at the base.The
ring shall be equipped with a group of calibrated jets, properly positioned so that they will direct
the flow of inlet water in such a way that microscopic particles of precipitated solids shall be
kept in suspension and exhausted from the water heater on that or successive hot water draws.
The burner(s) shall have an individual orifice for each burner tube and be constructed of tubular
aluminized or stainless steel mounted in an easily removable tray.
Water heater(s) shall have the CSA International seal of certification, a working pressure of 150 psi, a
factory-installed ASME rated temperature and pressure relief valve, and a 4˝ x 5˝ tank inspection port.
Manufactured under one or more of the
following U.S. Patent Numbers: 4,157,077;
4,263,879; 4,447,377; 4,527,543 and other
patents pending. Canadian Patent Numbers
1,151,480; 1,215,276 and other Canadian
patents pending.
In keeping with our policy of continuous product
improvement, specifications are subject to
change without prior notice.
Gas
E
F
G
H
I
Conn.
3
2
54
1
˝
2
3
2
54
1
˝
2
3
20
1
61
5
2
1
56
5
3
˝
4
8
4
8
4
3
20
1
60
1
2
1
55
1
3
˝
4
8
4
8
4
1
1
1
1
3
3
20
60
2
55
˝
4
8
4
8
4
4
19
3
61
1
2
1
56
3
˝
4
2
4
4
4
19
3
61
1
2
1
56
3
˝
4
2
4
4
+
4 or 6
21
3
63
1
2
1
58
1˝**
4
2
4
+
4 or 6
21
3
63
1
2
1
58
1˝**
4
2
4
3
-inch.
4
1
´ intervals.
2
1
˝ rise per foot.
4
4" Schedule 40 PVC*
6" Schedule 40 PVC*
N/A
N/A
N/A
N/A
N/A
N/A
135'
N/A
45'*
110'*
Printed in U.S.A.
Approx.
Shipping
Weight
(lbs.)
352
352
645
825
825
900
1010
900
1100

Advertisement

loading

This manual is also suitable for:

Sdv80-140Sdv100-260Sandblaster force sdv75 70neSandblaster force sdv75 70peSandblaster force sdv80 140neSandblaster force sdv100 199ne ... Show all