Spare parts/accessories
6.11 Controller Extension CX32
1) ALM = Active Line Modules; Basic Line Modules (BLM), and Smart Line Modules (SLM)
can also be used.
Note
Mixed operation of servo and vector-controlled drives
Mixed operation of servo and vector-controlled drives is not possible on a CX32. Therefore,
drives on a CX32 must be operated in servo or in vector mode only. As with the SIMOTION
D4x5, mixed operation of servo and V/f-controlled drives is possible on a CX32.
V/f-controlled drives
A maximum of 8 V/f-controlled drives are supported by each CX32.
The CX32 has the following interfaces:
● 4 DRIVE-CLiQ (X100 – X103)
● 4 digital inputs and 4 digital inputs/outputs (X122)
● Power supply (X124)
Additional references
You will find detailed information about the CX32 in the
80
CAUTION
The cooling clearances of 80 mm above and below the components must be observed.
Supplementary SINAMICS System Components for SIMOTION
SIMOTION D4x5
Commissioning and Hardware Installation Manual
Manual