PROFINET
The use of a Communication Board Ethernet (CBE30) enables SIMOTION D4x5 to
communicate with the following components via PROFINET:
Table 1- 4
Component
Programming device (PG/PC)
SIMATIC HMI device
Other controls (e.g. SIMOTION
or SIMATIC)
Master computer
Distributed I/O systems
SIMATIC ET 200M
SIMATIC ET 200S
SIMATIC ET 200pro
SIMATIC ET 200eco PN
Other PROFINET I/O
Drive units with PROFINET
interface
Gateways
DRIVE-CLiQ
The DRIVE-CLiQ interfaces permit a fast connection to the SINAMICS drive components.
DRIVE-CLiQ offers the following advantages within the DRIVE-CLiQ topology rules:
● Expandability of components
● Automatic detection of components by the control unit
● Standardized interfaces to all components
● Uniform diagnostics down to the components
● Complete service down to the components
● Simple mechanical handling
The controller can communicate with the following components via DRIVE-CLiQ:
D4x5
Manual, 05/2009
Components on the PROFINET
Function
... configures, sets parameters, programs, and tests using the
"SIMOTION SCOUT" Engineering System (ES).
... is used for operating and monitoring functions. This is not an
essential requirement for the operation of a Control Unit.
... e.g. higher-level controller (plant controller); modular machine
concepts with multiple controls, distributed across individual
machine modules
... communicates with other devices via UDP, TCP/IP.
Modular I/O system for control cabinet installation and high
channel densities.
Finely scalable I/O system for control cabinet installation and
particularly time-critical applications; including motor starters,
safety technology and individual grouping of load groups.
Modular I/O system with IP65/67 rating for machine-related
applications with no control cabinet; with features such as compact
designs, integrated PROFIsafe safety technology, PROFINET
connection and live module replacement.
Compact block I/O with IP65/66/67 degree of protection for
cabinet-free usage in machines with M12 connection method. Very
rugged and resistant encapsulated metal enclosure.
... convert speed setpoints into signals for controlling the motor
and supply the power required to operate the motors.
IE/AS-Interface link PN IO for the PROFINET IO gateway to
AS-Interface
PN/PN coupler for connecting two PROFINET IO networks
Description
1.2 System components
15