t-NEXT DF DX
TECHNICAL DATA
VERSION (1)
MODEL
SIZE
STEAM PRODUCTION
Power input
Absorbed current (OA)
Max absorbed current (FLA)
Water content
Max water supply pressure
NET WEIGHT (2)
HYDRAULIC CONNECTION
WATER INLET - ISO 228/1 – G M
WATER OUTLET - external diameter
1.
U = Under, downflow / O = Over, upflow
2.
Value to be added to the weight of the standard unit. Does not include the weight of the water content.
OPTIONAL ACCESSORIES : P051 – DEHUMIDIFICATION FUNCTION
OPTIONAL ACCESSORIES: P161 - T/RH AIR INTAKE SENSOR
OPTIONAL ACCESSORIES: P071 - REMOTE T/RH PROBE
OPTIONAL ACCESSORIES: 4666 – EXTERNAL AIR PROBE
T_tNEXTDFDX_0719_EN
U
U
117 P4 D
146 P4 D
E9
E9
kg/h
15
15
kW
11,3
11,3
A
16,2
16,2
A
23
23
l
10,3
10,3
Bar
1÷8
1÷8
kg
16
16
Ø
3/4"
3/4"
Ø mm
19
19
The optional requires mandatory accessory "P161 T/rH air intake sensor".
Components:
•
T / rH air intake sensor.
•
Electronic control system of the dew point temperature for the combined intervention of
cooling capacity and air flow.
P161: T/RH AIR INTAKE SENSOR
The accessory replaces the temperature sensor installed on the air intake in the unit and allows the
displaying of the relative humidity room value
The sensor is mandatorily required with following option:
•
4301 / 4303 / 4305 Humidifier;
•
P161 Dehumidification function;
•
P034 Intake free-cooling plenum.
P071: REMOTE T/RH PROBE
The accessory is added to the standard temperature sensor or to the temperature / humidity sensor
(optional) on the machine air intake. For indoor installation in a specific point of the room to be
conditioned.
The probe must be installed protected against atmospheric agent and allows the displaying of the
external air temperature.
The sensor is mandatorily required with following option:
•
P034 Intake free-cooling plenum.
46