Mitsubishi Electric t-NEXT DF DX 011 P1 S Manual page 12

Air conditioners for it cooling with dual fluid system.to be matched with remote air-cooled condenser.
Table of Contents

Advertisement

t-NEXT DF DX
T_tNEXTDFDX_0719_EN
P181 .................................... Network analyser (standard machine) Multifunction utility for calculating and
displaying the machine electrical measurements.
P182 .................................... Network analyser+optional (full optional machine) Multifunction utility for
calculating and displaying the machine electrical measurements.
P183 .................................... Kit network analyser (standard machine) Multifunction utility for calculating
and displaying the machine electrical measurements. Supplied in mounting
kit.
P184 .................................... Kit network analyser+optional (full optional machine) Multifunction utility
for calculating and displaying the machine electrical measurements. Supplied
in mounting kit.
A812 (2) .............................. Free-cooling direct control.
P021 .................................... 2 way 0-10V modulating water valve.2-way motorized valve with 0÷10
VDC control actuator and emergency manual control for the third way (by-
pass) of the chilled water hydraulic circuit. The valve is in combination with
the main water flow control valve
A431 .................................... Electric heater. Heating with electric heaters.
A432 .................................... Extra power electric heater. Size E1, E2 excluded.
4301 / 4303 / 4305 (3) ......... Humidification: Modulating steam humidifier with immersed electrodes
with electronic control.
4301 - Steam humidifier 3kg/h
4303 - Steam humidifier 8kg/h
4305 - Steam humidifier 15kg/h
P051 (4) .............................. Dehumidification function.
P161 .................................... T/rH air intake sensor. Combined Temperature / Humidity sensor on air
intake. The optional replace the standard temperature sensor on machine
air intake.
4666 .................................... External air probe. External air temperature probe.
P071 .................................... Remote T/rH probe. Combined Temperature / Humidity sensor for remote
installation. The optional is added to the standard temperature sensor on
machine air intake.
P111 / P112 / P113 / P114 . Dual power supply. Dual power supply with automatic change-over.
P111 - Dual power supply.
P112 - Dual power supply + optional.
P113 - Dual power supply kit. Supplied in mounting kit
P114 - Dual power supply kit + optional. Supplied in mounting kit
A381 .................................... Drain pump. Supplied in mounting kit. The system includes pump with
activation float and 10 linear meters long discharge pipe.
P084 .................................... Air filter ePM
EN 16890). Not compatible with "P017 / P018 / P019 Plenum + filter ePM
50%, ePM
A531 (5) .............................. On-off damper. Non-return air damper with frame driven by electric
servomotor installed on the machine air delivery.
P011 .................................... Empty plenum.
P012 .................................... Empty plenum CL.A1. Plenum with fire reaction in class "0" or "A1".
P013 .................................... Plenum + 3 grilles on three sides with double adjustable row.
P014 .................................... Plenum + 3 grilles CL.A1. Plenum with grilles on three sides with double
adjustable row, with fire reaction in class "0" or "A1".
P015 .................................... Silenced plenum. Not compatible with "P084 Air filter ePM10 50%.".
P016 .................................... Silenced plenum + 1 grille. Grille with double adjustable row on front side
and sound absorbers.
P017 .................................... Plenum + filter ePM
to ISO EN 16890). Not compatible with "P084 Air filter ePM10 50%.".
P018 .................................... Plenum + filter ePM
to ISO EN 16890). Not compatible with "P084 Air filter ePM10 50%.".
P019 .................................... Plenum + filter ePM
to ISO EN 16890). Not compatible with "P084 Air filter ePM10 50%.".
P031 (6) .............................. Empty intake plenum.
P032 (6) .............................. Empty intake plenum CL.A1. Plenum with fire reaction in class "0" or "A1".
(size E0 excluded).
P034 (7) .............................. Intake free-cooling plenum.
P041 / P042 / P043 ............. Support frame with height adjusting rubber holders. Supplied in mounting
kit. It is not possible to match the support frame with plenum installed under
the machine.
P041 – Support frame h 255-350mm
P042 – Support frame h 355-450mm
P043 – Support frame h 400-510mm
3601 .................................... Compressor operating signal contact. Voltage free contact for
compressor status signalling.
12
50%. Washable high efficiency air filter (according to ISO
10
50%, ePM
85% (according to ISO EN 16890)".
1
1
50%. Plenum with high efficiency air filter (according
2,5
50%. Plenum with high efficiency air filter (according
1
85%. Plenum with high efficiency air filter (according
1
2.5
MEHITS S.p.A.
DATA BOOK