THERMAL & REFRIGERATION ENERGY METER WITH
ENERGY & VOLUME PULSE TRANSMITTER
Conforms to UNI EN 1434 standard
Conforms to Directive MID 2004/22/EC
IET 7183 C1
(230 V ~) Eng.
IET 7143 C1
(24 V ~) Eng.
• Automatic energy metering :
– consumption of thermal (heating) and/or refrigeration (conditioning) energy;
• Forwarding of energy and volume pulses:
–two optoisolated outputs for each energy & volume metering unit
• Volumetric meter :
– mechanical or electronic meters (e.g. ultrasound, see section 10.2)
• Communication system already incorporated:
– C-Bus for Telemanagement via modem or local management via PC
speed programmable from 1200 to 9600 baud
• 1 remote control output
– enabling remote control via Telemanagement
• Installation on pipework or on DIN rail
• Power supply : IET 7183 = 230 V
– battery incorporated for power in event of mains failure
QUICK REFERENCE :
– INSTALLATION & WIRING DIAGRAM: SECTIONS 8, 9 & 10
– TESTING WIRING: SECTION 21
– ACCURACY RATING OF THE SYSTEM: SECTION 14
– SIMPLIFIED READ out OF THE UNIT: SECTION 16
– COMPLETE READOUT: SECTION 18
– SETTING FISCAL PARAMETERS: SECTION 20
1. APPLICATION
The "universal" meter IET 7183 (or IET 7143), in conjunction with a volumetric meter, calculates the thermal and/or
refrigeration energy used in heating and/or air conditioning zones.
By means of C-Bus communication the meter can be connected locally or via Telemanagement to a PC for readouts
locally or at a remote site.
As of firmware version 13, transmission speed is programmable from 1200 to 9600 baud.
2. PRINCIPAL FUNCTIONS
– METERING THERMAL & REFRIGERATION ENERGY: the volumetric meter sends the pulses from measuring the
volume of hot and/or cold water for metering as calories and/or frigories; while the flow and return sensors send the
temperature values; the unit processes this data and calculates continuously the related energy, integrates it and
records it.
– FORWARDING ENERGY & VOLUME PULSES: the unit is provided with two optoisolated outputs; each genera-
tes a pulse each time a certain quantity of energy is metered and of water flowing past.
The measurement unit for volume and energy depend on the nominal flow of the volumetric meter.
– POWER SUPPLY: one of the two models is usually powered by 230 V~ and the other by 24 V~; a battery is
incorporated which guarantees operation in the event of a temporary power failure. The battery will ensure opera-
tion for about three years of power failure.
– DATA RECORDING: all the basic data is recorded in two copies physically separated; a security system permits
protecting this data from any critical events and restoring the original data.
– DATA RECORDING (LOGGER): all consumption data is recorded every week for 52 weeks; this represents a
complete annual season of heating and air conditioning. Moreover, each week is recorded the peak (weekly) of
the flow and of the power; these figures are processed at a programmable time interval
– ALARM SYSTEM: the unit processes10 different types of alarm with a local or remote output; the alarms are
recorded in the DATA LOGGER by type and time of event.
– ADDITIONAL PROCESSING: the unit continuously processes the flow of the fluid vector and the instantaneous
power of the system. Moreover, it provides all the data of interest to a normal user and configuration data for the
supervising engineer.
– REMOTE CONTROL: the unit is provided with a Remote Control output which can be enabled via Telemanage-
ment; its most common use is switching off the heating (e.g. closure of zone valve) for the user in arrears.
3. TEMPERATURE SENSORS
IET 7183 and IET 7143 are provided with two Pt 1000 temperature sensors calibrated in pairs, each with an electric
cable of about 3 metres.
Each of the two sensors is inserted in a pocket the length of which depends on the application.
We reserve the right to make changes without notice
COSTER
~
; IET 7143 = 24 V ~
H 355 - IET 7143-7183 C1 Eng.
C
BUS
Rev. 06
18.01.10 AM
H 355
18.01.10 AM
Rev. 06
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IET 7143 C1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Coster IET 7143 C1

  • Page 1 Conforms to UNI EN 1434 standard Conforms to Directive MID 2004/22/EC IET 7183 C1 (230 V ~) Eng. IET 7143 C1 (24 V ~) Eng. • Automatic energy metering : – consumption of thermal (heating) and/or refrigeration (conditioning) energy; • Forwarding of energy and volume pulses: –two optoisolated outputs for each energy &...
  • Page 2: General Technical Data

    COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM 4. GENERAL TECHNICAL DATA Ambience Class A Ambient temperature : Calculation units - operation 5 to 55 °C Conforms ro Directive MID 2004/22/EC - storage – 25 to + 60 °C...
  • Page 3 COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM 7. TEMPERATURE SENSORS & RELATED POCKETS Important instructions for the correct installation of the sensors – The sensors are inserted in the pockets and pressed as far as they will go, in order to be sure that they detect the fluid temperature;...
  • Page 4: Electrical Connections

    COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM 8. SITING & INSTALLATION The unit must be installed in a dry location that respects the permitted ambient conditions given under 4. TECHNI- CAL DATA. ”. It must be connected to an electrical installation constructed according to standard IEC 79-14 (CEI...
  • Page 5: Wiring Diagram

    M of the terminal block. – in the event of doubt or where there are existing installations which fall outside this advice, consult COSTER tech- nical staff to find solutions that do not require the re-design of the wiring.
  • Page 6 Example of application: automatic limitation of the primary flow in District Heating sub-stations. If COSTER XTT 618 or XTT 608 controllers are used, please refer to the application examples provided in technical factsheets B 283, page 3 (XTT 618) and B 284, page 4 (XTT 608).
  • Page 7 COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM 13. ACCURACY OF THE CALCULATION UNIT The maximum error of the calculation unit is less than that required by EN 1434 (2007) Directive. This maximum error is shown in the following formula: ∆...
  • Page 8 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM We reserve the right to make changes without notice...
  • Page 9 COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM 16. MINIMUM INDISPENSABLE SETTING OPERATIONS; SIMPLIFIED READOUT OF UNIT In this section are described the minimum indispensable settings and other operations essential for correct operation of the unit and the simplified readout..
  • Page 10 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM The difference in temperature between flow and return; this difference will be positive with heating 0 1 1 . 0 3 C – c and negative when there is conditioning.
  • Page 11: Functions Of The System

    The triggering of any type of alarm is signalled via output A+, A0 (terminals 50 and 51), which remains closed so long as the alarm status remains: this output is compatible with the alarm inputs of any COSTER electronic device and so can be managed in the same way as any type of site alarm.
  • Page 12 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM Calculation of flow of vector fluid and of instantaneous power On the basis of the signal received from the volumetric meters the instantaneous flow in m /h is calculated and also the instantaneous power in Kw which at that moment is being supplied to the site.
  • Page 13 Telemanagement The unit is provided with C-BUS (COSTER – BUS SLAVE) for local or remote readout of all the data. As of firmware version 13, transmission speed is programmable from 1200 to 9600 baud.
  • Page 14 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM COMPLETE READOUT OF THE UNIT & NON-FISCAL SETTINGS The complete readout of the unit starts from the simplified readout already described in section 16: for each of the pages M1 …M.8 there may exist subpages with further information, usually regarding the starting page, and for...
  • Page 15 COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM Temperature menu The menu for temperature of flow & return and for the difference between the two does not have sub-menus. 0 5 1 . 0 5 ° C 0 4 0 .
  • Page 16 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM We reserve the right to make changes without notice...
  • Page 17: View From Above

    COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM 20. SETTING FISCAL PARAMETERS & PROGRAMMING ALARMS The fiscal parameters have a direct influence on the metering of the whole system; in order to change these para- meters it is necessary to open the seals on the unit (see section 5) and take certain actions inside the meter.
  • Page 18 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM Switch number 8: choice between “normal use menu” and “menu for fiscal settings” Using this switch you can enter the menu for fiscal settings = NORMAL OPERATING MENU: this is the menu for the normal use of IET 71.. ; it does not permit adjustments to fiscal data.
  • Page 19 COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM FISCAL SETTINGS COOLING SIDE & SETTING ALARMS 3 TF 4 TF to menu 0 7 8 9 3 1 2 . 3 0 0 1 2 3 4 . 5 6...
  • Page 20 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM FISCAL SETTINGS COOLING – OVERHAUL ALARM 5 TF 6 TF RETURN 0 7 8 9 3 1 2 . 3 0 0 0 4 3 8 0 0...
  • Page 21 Trigger any alarm (the simplest way is to disconnect a sensor) and check that the output really does respond, once it has been connected to a receiver of any type (e.g. standard alarm inputs for COSTER electronic devices). The testing can also be carried out using a normal tester, exchanging the probes if necessary, and bearing in mind that the output is of the OPEN COLLECTOR type.
  • Page 22 COSTER H 355 - IET 7143 - 7183 C1 Eng. Rev. 06 18.01.10 AM 22. DATA WHICH CAN BE SET ONLY VIA TELEMANAGEMENT Certain functions with their respective parameters can be set and adjusted only via Telemanagement using a local or remote PC and by an administrator authorised to operate at the highest level of the SWC 701 program.
  • Page 23 COSTER H 355 - IET 7143-7183 C1 Eng. Rev. 06 18.01.10 AM We reserve the right to make changes without notice...
  • Page 24 Via S. Longanesi, 14 Tel. +39 065573330 ENERGIA 00146 - Roma Fax +39 065566517 COSTER TECNOLOGIE ELETTRONICHE S.p.A. Shipping Sede Legale: 20132 Milano - Via San G.B. De La Salle, 4/a Via Gen. Treboldi, 190/192 Tel. +39 0364773200 25048 - Edolo (BS) Tel.

This manual is also suitable for:

Et 7183 c1

Table of Contents