7.1.4 Timer 0, 1 Control Register
The following four types of registers control timer 0, 1.
• 16-bit timer mode control register n (TMCn)
• Capture/compare control register n (CRCn)
• 16-bit timer output control register n (TOCn)
• Prescaler mode register 0n (PRMn)
(1) 16-bit timer mode control register 0, 1 (TMC0, TMC1)
This register specifies the operation mode of the 16-bit timer; and the clear mode, output timing, and overflow
detection of the 16-bit timer register n.
TMCn is set by a 1-bit or 8-bit memory manipulation instruction.
RESET input clears TMC0 and TMC1 to 00H.
Caution The 16-bit timer register n starts operating when TMCn2 and TMCn3 are set to the value
other than 0, 0 (operation stop mode). To stop the operation, set TMCn2 and TMCn3 to 0, 0.
150
CHAPTER 7
TIMER/COUNTER FUNCTION