Page 9
SIReB Basic RDS E SIReB1 SIReRTX SIReUB1 (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB Basic - Parallel connection SIReB1 SIReB1 SIReRTX SIReUB1 (optional) 230V~ 230V~ ROOM ROOM Pot. Pot. Unit ID Unit ID ACTUATOR SUPPLY ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
Page 10
SIReB Basic RDS W SIReB1 SD230 SIReRTX SIReUB1 (optional) ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY...
Page 11
SIReB Basic - Parallel connection RDS W SIReB1 SD230 ROOM 230V~ Pot. Unit ID ACTUATOR SUPPLY SIReB1 SD230 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReB1 SD230 SIReUB1 SIReRTX (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe.
Page 12
Output charts water Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure flow drop flow drop position water air temp.
Page 13
42,0 0,56 50,8 26,4 30,0 0,32 17,6 3100 14,4 30,0 0,14 16,7 33,9 0,20 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
Page 15
Assembly and operating instructions General Instructions can carry the weight of the air curtain and Read these instructions carefully before duct. The estimated weight of the installation installation and use. Keep this manual for is stated in the Technical specifications. If the future reference.
Page 16
(included agents. in Frico valve kits) to allow problem free removal. A vent valve should be connected at a Overheating high point in the pipe system. Air valves are not...
Page 17
Fan replacement For units with electrical heating, check also the Fans are replaced through the bottom service following: • Power supply to electric heater coil; check hatch. Alternatively the screws of the bottom fuses and circuit-breaker (if any). service hatch are slackened and the fans are •...
Page 18
Safety • For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used. • Keep the areas around the air intake and exhaust grilles free from possible obstructions! • During operation the surfaces of the unit can be hot! •...
Page 21
Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 Fax: +46 31 26 28 25 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...